In the hazardous waste combustor MACT rule at 63.1209(m) (4) (D) (ii) there is arnrequirement to “—establish a limit on minimum pressure drop and maximum pressurerndrop across each baghouse cell based on manufacturer’s specifications.” The agency hasrnstated that this requirement is an operating parameter limit to insure the particulate matterrncontrol device is operating in a manner that will control PM, and to alert the operatorrnwhen the device falls outside the operating limit.rnIndustry representatives have argued that pressure drop across each cell of arnbaghouse is not a good indicator of baghouse cell failure, and in fact small holes in bagsrnthat lead to large PM emissions can not be detected by changes in pressure drop. This isrnespecially true for big baghouse with a large volume of airflow.rnThis presentation will provide factual evidence that changes in pressure droprnacross individual cells of a large baghouse cannot be correlated to changes in particulaternemissions, and that parameters such as opacity are much better predictors of baghousernperformance. Actual pressure changes from an individual cell of a baghouse will bernpresented to demonstrate the resulting changes in pressure between off-line cleaningrnevents.
机译:在危险废物燃烧室MACT规则63.1209(m)(4)(D)(ii)中,有以下要求:“-根据制造商的规格,确定每个袋式除尘器室之间的最小压降和最大压降极限。”该机构已声明此要求是一个操作参数限制,以确保颗粒物控制设备以可控制PM的方式运行,并在设备超出操作限制时向操作员发出警报。行业代表认为,每个单元上的压降arnbaghouse的值并不是袋式除尘器单元故障的良好指标,实际上,袋式除尘器中的小孔会导致大量PM排放,而压降变化无法检测到。这特别适用于具有大量气流的大型布袋除尘器。rn该演示文稿将提供事实证据,表明大型布袋除尘器各个单元之间的压降变化与颗粒物排放的变化无关,并且诸如不透明度之类的参数可以更好地预测布袋除尘器的性能。将显示来自集尘室单个单元的实际压力变化,以演示离线清洗事件之间压力的最终变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号