In air conditioning applications premature failure of copper tubing frequently occurs due tornpitting corrosion after a short period in service and even during leakage tests after installation. Thisrntype of corrosion is described in the literature as ant-nest (formicary) corrosion. Ant-nest corrosionrnmorphology is characterized by microscopic caverns connected by tunnels.rnCopper tubes used in a commercial air conditioning system were analyzed to assess the reasons forrntheir premature corrosion failure during leakage tests after installation and during their first two monthsrnin service. Scanning electron microscopy (SEM), energy dispersive X-ray (EDX) analysis and X-rayrnphotoelectron spectroscopy (XPS) were the techniques utilized. Volatile organic acids, chlorine andrnsulfur, originated by the manufacturing processes, were identified as possible sources of the prematurerncopper corrosion failure.
机译:在空调应用中,铜管过早失效通常是由于在短时间使用后甚至在安装后进行泄漏测试时由于裂孔腐蚀引起的。这种腐蚀在文献中被描述为蚁巢(正式)腐蚀。蚁巢腐蚀形态的特征是通过隧道连接的微观洞穴。对商用空调系统中使用的铜管进行了分析,以评估其在安装后以及服务的前两个月内进行渗漏测试时过早腐蚀失败的原因。使用了扫描电子显微镜(SEM),能量色散X射线(EDX)分析和X射线光电子能谱(XPS)。生产过程中产生的挥发性有机酸,氯和硫被确定为铜过早腐蚀失效的可能来源。