LCL filter offers a better choice of attenuating switching frequency harmonics, since compared with L or LC filters the value of required inductance is smaller. But LCL filter may cause resonance which is a disaster for the system's stability. In order to solve the problem, a twocurrent-loop control strategy which includes grid-current outer loop and filter-capacitor-current inner loop is used here. The filter-capacitor-current is chosen as the inner loop to damp the resonance. The implementation of this strategy is easy and the system performance is good. However, the tuning procedure is complex since the outer and inner controller can not cooperate well if the parameters of the controllers are not suitable and there is no one paper which provides a method to calculate the exact value of the two-current-loop controller's parameters. This paper proposed a specific method to give out the accurate value of the controller parameters relating to certain performance. The practicability of the method is tested and the anti-distortion ability of the system is analyzed. Finally experimental results verify the availability and correctness of the proposed method.
机译:LCL滤波器为衰减开关频率谐波提供了更好的选择,因为与L或LC滤波器相比,所需电感的值更小。但是LCL滤波器可能会引起共振,这对于系统的稳定性是一个灾难。为了解决该问题,这里采用了包括电网电流外环和滤波电容器电流内环的双电流环控制策略。选择滤波电容电流作为内部环路以抑制谐振。该策略易于实施,系统性能良好。但是,调整过程很复杂,因为如果控制器的参数不合适,外部控制器和内部控制器将无法很好地配合,并且没有一篇论文提供一种方法来计算两电流环控制器的精确值。本文提出了一种特定的方法来给出与某些性能有关的控制器参数的准确值。测试了该方法的实用性,并分析了系统的抗失真能力。最后实验结果验证了该方法的有效性和正确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号