首页> 外文OA文献 >Simplified Seismic Design for Mid-Rise Buildings with Vertical Combination of Framing Systems
【2h】

Simplified Seismic Design for Mid-Rise Buildings with Vertical Combination of Framing Systems

机译:垂直组合框架系统的中高层建筑的简化抗震设计

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

The mid-rise building with vertical combination of framing systems consists of a structural system in which the seismic-force-resisting-system (SFRS) of the upper structure is commonly a lightweight structural system such as cold-formed steel (CFS) frame or wood frame, while the SFRS associated with the lower one adopts a traditional structural system, such as reinforced concrete (RC) or structural steel frame. In current practice, the presence of: (a) vertical irregularities on mass and stiffness, and (b) damping difference between lower and upper structures creates challenges for the seismic design of such buildings. Presented in this thesis is research with aiming to solve the challenges arising from the foregoing two aspects in relatively simple and practical ways.Because of the mass irregularity in the vertical direction, the stiffness arrangement for the lower and upper structures in the combined framing system is quite different from that of the “regular” building. A simplified approach is proposed for the determination of storey-stiffness arrangements of such buildings based on the pre-determined mass distribution and specified storey drift limit. In addition, by considering both the mass and stiffness irregularities, two manually-based simplified methods, i.e., modified equivalent lateral force procedure (ELF) and two-stage analysis procedures, are proposed to evaluate seismic loads of the combined framing systems. The simplified approaches to determine the required storey-stiffness arrangements and compute seismic loads are developed based on the USA standard American Society of Civil Engineers 7 (ASCE 7) (ASCE, 2010) at first. Then, by considering the difference in seismic design provisions between ASCE 7 and the Canadian code National Building Code of Canada 2010 (NBCC 2010) (NBCC, 2010), several modifications are made on the simplified approaches based on ASCE 7 for their Canadian application.In the proposed approach to evaluate the storey-stiffness arrangements, the effects of the interaction between the lower and upper structures in terms of mass and stiffness on the seismic load are investigated. The feasible stiffness arrangements can be obtained based on the required relationship between the stiffness of the lower structure and that of the upper one determined by the proposed approach. Two examples are presented to demonstrate the efficiency of the proposed approach. The result obtained from the proposed approach is justified by the code-specified modal response spectrum analysis. The two examples demonstrate that the relative seismic weight between the lower and upper structures has a significant influence on the required stiffnesses of the lower and upper structures. In general, when the number of the storey and total seismic weight associated with the lower structure are much greater than those of the upper one, the required stiffness of the upper structure will be greatly affected by the interaction between lower and upper structures in terms of mass and stiffness. On the other hand, if the number of the storey and total seismic weight associated with the lower structure are much smaller than those of the upper one, such interaction has less effect on the required stiffness of the upper structure. In such case, the required stiffness of the upper structure is based primarily on the characteristics of the upper structure. The modified ELF procedure is applied to the combined framing systems in which there is only one-storey upper structure. Both the applicable requirements and seismic load distributions associated with the modified ELF procedure are proposed. If the storey-stiffness ratio between lower and upper structures is less than a specific value designated as rkb1, the lower structure is dominated primarily by the first mode and the traditional ELF procedure can be used to approximate the seismic load of the lower structure. However, the seismic load of the one-storey upper structure may still be underestimated as the behaviour of the upper structure may be dominated by higher vibration modes of the entire structure. Consequently, the shear force of the one-storey upper structure cannot be estimated based on the traditional ELF procedure. Equations for evaluating the shear force of the one-storey upper structure are presented in the modified ELF procedure.The two-stage analysis procedure prescribed in ASCE 7 (ASCE, 2006; 2010) ignores the interaction between lower and upper structures in terms of mass and stiffness and permits the lower and upper structure to be analyzed by the conventional ELF procedure, separately. New applicable requirements and seismic load distributions associated with the two-stage analysis procedures are proposed. The proposed procedure is compared with that prescribed in ASCE 7. It is found the stiffness requirement of ASCE 7 two-stage analysis procedure may be inappropriate, which may result in the underestimation of the base shear force of the upper structure in certain cases. Furthermore, the shear force for the top storey of the upper structure may also be considerably underestimated by the ASCE 7 two-stage analysis procedure. Therefore, an additional top shear force is to be applied to the top of upper structure. Equations to compute the additional top shear force are also provided. The accuracy of the proposed two-stage analysis procedure, either the one based on both ASCE 7 or the one based on NBCC 2010, is greatly improved compared to that prescribed in ASCE 7 (ASCE, 2006; 2010).Finally, damping difference between lower and upper structures in the combined framing system is investigated. By assuming the combined framing systems are classically damped, i.e., the damping matrix of the combined framing systems is orthogonal to the un-damped mode shape, an analytical method to approximate the equivalent modal damping ratio for the case where lower and upper structures have different damping ratios is proposed. However, as the combined framing system in fact is non-classically damped, if the lower and upper structures have different damping ratios, the proposed approximation of the equivalent modal damping ratio may lead to significant errors on seismic load in certain cases. Therefore, errors on seismic loads resulted from the classical damping approximation, which determine whether the proposed equivalent modal damping ratio is acceptable or not, are investigated. It is found large errors of seismic response associated with the proposed equivalent modal damping ratio usually occur when the dominating modes of the structures have closely spaced natural frequencies. However, for most combined framing systems in practice, the dominating modes have well separated natural frequencies and the proposed equivalent modal damping ratio is applicable to evaluate the seismic response of the combined framing systems. In addition, a new index of damping non-proportionality is suggested in this study to quantify the extent of non-proportional damping.
机译:垂直组合框架系统的中层建筑由结构系统组成,其中上部结构的抗震系统(SFRS)通常是轻型结构系统,例如冷弯型钢(CFS)框架或木框架,而与下部框架相关的SFRS采用传统的结构系统,例如钢筋混凝土(RC)或钢结构框架。在当前实践中,存在以下问题:(a)质量和刚度在垂直方向上不规则,以及(b)上下结构之间的阻尼差异为此类建筑物的抗震设计带来了挑战。本论文的研究旨在以相对简单和实用的方式解决上述两个方面的挑战。由于垂直方向的质量不规则性,组合框架系统中上下结构的刚度布置为与“常规”建筑完全不同。提出了一种简化的方法,用于基于预定的质量分布和指定的楼层漂移极限来确定此类建筑物的楼层刚度布置。此外,考虑到质量和刚度的不规则性,提出了两种基于人工的简化方法,即改进的等效侧向力程序(ELF)和两阶段分析程序,以评估组合框架系统的地震荷载。首先根据美国标准美国土木工程师学会7(ASCE 7)(ASCE,2010)开发了用于确定所需的层间刚度布置和计算地震荷载的简化方法。然后,通过考虑ASCE 7与加拿大规范加拿大国家建筑规范2010(NBCC 2010)(NBCC,2010)之间在地震设计规定方面的差异,对基于ASCE 7的简化方法在加拿大的应用进行了一些修改。在所提出的评估储层刚度布置的方法中,研究了上部和下部结构之间在质量和刚度方面的相互作用对地震荷载的影响。可以基于由所提出的方法确定的下部结构的刚度和上部结构的刚度之间的所需关系来获得可行的刚度布置。给出两个例子,以证明所提出方法的效率。通过代码指定的模态响应频谱分析可以证明从该方法获得的结果是合理的。这两个示例表明,下部和上部结构之间的相对地震权重对下部和上部结构所需的刚度具有重大影响。通常,当与下部结构相关的层数和总地震权重比上部结构大得多时,下部结构和上部结构之间的相互作用会极大地影响上部结构的所需刚度。质量和刚度。另一方面,如果与下部结构相关联的层数和总地震重量远小于上部结构,则这种相互作用对上部结构所需的刚度的影响较小。在这种情况下,上部结构的所需刚度主要基于上部结构的特性。修改后的ELF程序适用于只有一层高层结构的组合框架系统。提出了与改进的ELF程序相关的适用要求和地震荷载分布。如果下部结构和上部结构之间的储层刚度比小于指定为rkb1的特定值,则下部结构主要由第一模式主导,并且传统的ELF程序可用于估算下部结构的地震荷载。然而,由于高层结构的行为可能会受到整个结构的较高振动模式的支配,因此单层高层结构的地震载荷仍可能被低估。因此,不能根据传统的ELF程序来估算一层高层结构的剪力。改进的ELF程序提供了评估高层结构剪力的公式.ASCE 7(ASCE,2006; 2010)中规定的两阶段分析程序在质量方面忽略了上下结构之间的相互作用硬度和刚度,并允许分别通过常规ELF程序分析下部和上部结构。提出了与两阶段分析程序相关的新的适用要求和地震荷载分布。将拟议的程序与ASCE 7中规定的程序进行了比较。发现ASCE 7两阶段分析程序的刚度要求可能不合适。,在某些情况下可能会低估上部结构的基础剪力。此外,ASCE 7两阶段分析程序还可能大大低估了上部结构顶层的剪切力。因此,附加的顶部剪切力将施加到上部结构的顶部。还提供了计算附加顶部剪力的公式。与ASCE 7(ASCE,2006; 2010)中规定的方法相比,拟议的两阶段分析程序(基于ASCE 7的一种或基于NBCC 2010的一种)的准确性大大提高了。研究了组合框架系统中的下部和上部结构。通过假设组合框架系统是经典阻尼的,即,组合框架系统的阻尼矩阵与无阻尼模态正交,则一种分析方法可以近似估算上下结构不同时的等效模态阻尼比。提出了阻尼比。但是,由于组合框架系统实际上是非经典阻尼的,因此,如果下部结构和上部结构的阻尼比不同,则建议的等效模态阻尼比的近似值在某些情况下可能会导致地震荷载的重大误差。因此,研究了由经典阻尼近似引起的地震载荷误差,该误差确定了拟议的等效模态阻尼比是否可接受。已经发现,当结构的主导模态具有紧密间隔的固有频率时,通常会发生与拟议的等效模态阻尼比相关的地震响应大误差。但是,对于大多数实践中的组合框架系统,主导模式具有很好的分离固有频率,并且所提出的等效模态阻尼比可用于评估组合框架系统的地震响应。另外,在这项研究中提出了新的阻尼非比例阻尼指标来量化非比例阻尼的程度。

著录项

  • 作者

    Yuan Xiaoli;

  • 作者单位
  • 年度 2016
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号