首页> 外文OA文献 >Commonly applied positive end-expiratory pressures do not prevent functional residual capacity decline in the setting of intra-abdominal hypertension: a pig model
【2h】

Commonly applied positive end-expiratory pressures do not prevent functional residual capacity decline in the setting of intra-abdominal hypertension: a pig model

机译:常见的呼气末正压通气不能防止腹内高压时功能残余容量的下降:猪模型

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

IntroductionudIntra-abdominal hypertension is common in critically ill patients and is associated with increased morbidity and mortality. The optimal ventilation strategy remains unclear in these patients. We examined the effect of positive end-expiratory pressures (PEEP) on functional residual capacity (FRC) and oxygen delivery in a pig model of intra-abdominal hypertension.ududMethodsudThirteen adult pigs received standardised anaesthesia and ventilation. We randomised three levels of intra-abdominal pressure (3 mmHg (baseline), 18 mmHg, and 26 mmHg) and four commonly applied levels of PEEP (5, 8, 12 and 15 cmH2O). Intra-abdominal pressures were generated by inflating an intra-abdominal balloon. We measured intra-abdominal (bladder) pressure, functional residual capacity, cardiac output, haemoglobin and oxygen saturation, and calculated oxygen delivery.ududResultsudRaised intra-abdominal pressure decreased FRC but did not change cardiac output. PEEP increased FRC at baseline intra-abdominal pressure. The decline in FRC with raised intra-abdominal pressure was partly reversed by PEEP at 18 mmHg intra-abdominal pressure and not at all at 26 mmHg intra-abdominal pressure. PEEP significantly decreased cardiac output and oxygen delivery at baseline and at 26 mmHg intra-abdominal pressure but not at 18 mmHg intra-abdominal pressure.ududConclusionsudIn a pig model of intra-abdominal hypertension, PEEP up to 15 cmH2O did not prevent the FRC decline caused by intra-abdominal hypertension and was associated with reduced oxygen delivery as a consequence of reduced cardiac output. This implies that PEEP levels inferior to the corresponding intra-abdominal pressures cannot be recommended to prevent FRC decline in the setting of intra-abdominal hypertension.
机译:简介 ud腹内高压在重症患者中很常见,并且与发病率和死亡率增加相关。这些患者的最佳通气策略仍不清楚。我们在腹内高压猪模型中检查了呼气末正压通气(PEEP)对功能残余容量(FRC)和氧气输送的影响。 ud udMethods ud13头成年猪接受了标准的麻醉和通气。我们将腹腔内压力的三个水平(基线为3 mmHg,18 mmHg和26 mmHg)和四个PEEP的常用水平(5、8、12和15 cmH2O)随机化。腹腔内压力是通过使腹腔内气球膨胀而产生的。我们测量了腹内(膀胱)压力,功能残余容量,心输出量,血红蛋白和血氧饱和度,并计算了氧气输送量。 ud ud结果 ud升高的腹内压力降低了FRC,但并未改变心输出量。 PEEP在基线腹腔内压力时会增加FRC。 PEEP在腹腔内压力为18 mmHg时,FRC随腹腔内压力升高的下降部分被抵消,而在腹腔内压力为26 mmHg时则完全没有。 PEEP显着降低基线和腹腔内压力为26 mmHg时的心排血量和氧气输送量,但腹腔内压力为18 mmHg时不降低。预防由腹腔内高压引起的FRC下降,并由于心排血量减少而导致氧气输送减少。这意味着不能推荐低于腹腔内相应压力的PEEP水平来防止FRC在腹腔内高压中的下降。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号