首页> 外文OA文献 >The impact of nanosilver addition on element ions release form light-cured dental composite and compomer into 0.9 NaCl.
【2h】

The impact of nanosilver addition on element ions release form light-cured dental composite and compomer into 0.9 NaCl.

机译:纳米银添加对元素离子释放的影响将光固化的牙科复合材料和复合材料形成0.9%NaCl

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this paper was to identify and to assess in semi-quantified way the release of different ions from composite and compomer restorative materials subjected to 0.9% NaCl solution, which simulates the environment of the human body. In the present study, the number of ions (Al, Ag, Ba, Sr, Ti) released from dental fillings over time (one week, one month and 3 months), in different temperatures (23°C, 37°C) and depending on the materials applied (unmodified/modified with nanosilver) was investigated. The results suggest that nanosilver addition influences directly on the process of metal ion releasing into 0.9% NaCl solution. The increase in the number of counts of metal ions was observed in the solutions in which samples modified with nanosilver were kept. Higher amount of metal ion release was observed for composite samples rather than for compomer materials. The study revealed that in general the number of released metal ions increases with the time of storage (for metal ions: Ti, Ba, Sr) and at higher temperature (Ag, Ti, Ba). Reverse tendency observed for silver ion release versus incubation time may be caused by the process of silver adsorption, which takes place on the surface of analyzed material and test-tube walls, where samples were incubated.
机译:本文的目的是识别并以半量化方式评估从复合材料和传统恢复材料的不同离子释放到0.9%NaCl溶液,这模拟了人体的环境。在本研究中,随着时间的推移(一周,一个月,3个月),在不同温度(23°C,37°C)和牙科填充物(一周,一个月,3个月)中,离子(Al,Ag,Ba,Sr,Ti)的数量(一周,一个月,一个月,37°C)和根据所施加的材料(未经修改/改性用纳米ilver)进行了研究。结果表明,纳米ilver直接影响金属离子释放到0.9%NaCl溶液的过程中的影响。在保持用纳米ilver改性的样品的溶液中观察到金属离子数量的增加。对于复合样品而不是用于传感材料,观察到较高量的金属离子释放。该研究表明,通常,释放金属离子的数量随着储存时间(用于金属离子:Ti,Ba,Sr)和更高温度(Ag,Ti,Ba)而增加。对于银离子释放而观察到的逆转趋势可能是由银吸附过程引起的,这在分析的材料和试管壁上发生,其中孵育样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号