首页> 外文OA文献 >Effect of 35 sodium ascorbate on microtensile bond strength of composite resin immediately after bleaching
【2h】

Effect of 35 sodium ascorbate on microtensile bond strength of composite resin immediately after bleaching

机译:35%抗坏血酸钠对复合树脂立即漂白后微拉伸强度的影响

摘要

Background: Sodium ascorbate has been recently tested to reverse the temporary weakening of composite bonding when its application is done immidiately after bleaching. This study compared the microtensile bond strength of immediate and delayed bonding of composite after bleaching, with and without the application of 35% sodium ascorbate. Objective: to assess the effect of 35% sodium ascorbate (SA) (Sigma-Aldrich Co.) on microtensile bond strength of dentin immediately after bleaching with 35% hydrogen peroxide (Pola Office/SDI). Methods: Twenty-five sound human 3rd molars were collected in order to obtain one hundred twenty five specimens. Teeth were randomly divided into five groups: Grp1 (bleaching + immediate restoration), Grp2 (bleaching + delayed restoration), Grp3 (bleaching + SA + immediate restoration), Grp4 (bleaching + SA + delayed restoration), Grp5 (Control-no treatment). After bleaching, but prior to restoration, Grps 2 u26 4 were stored for 1 week in deionized water at 37°C. All samples were restored using Optibond Solo Plus (Kerr) and Filtek Supreme Ultra (3M/ESPE) following manufacturersu27 instructions. Teeth were sectioned into 1x1 mm bars, obtaining around 10 bars from each tooth. Microtensile bond strength was measured with a universal testing machine (Instron, model 8841) at a crosshead speed of 0.5 mm/min. Results: Descriptive statistics revealed that Grp1 (positive control) showed significant reduction in microtensile bond strength (34.17 ± 10.78). Grp5 (negative control)(45.83 ± 19.32), Grp2 (standard of care)(45.36± 16.57), Grp3 (45.06 ± 20.91) and Grp4 (44.73 ± 16.85) showed statistically similar microtensile bond strength. One-way ANOVA was used to determine if differences were evident between the five groups. Microtensile bond strength differed significantly across the five groups (F (4, 1073.81) = 3.54, p = .007) Tukeyu27s post-hoc comparisons of the five groups showed significant differences between Grp 1 and all other groups 2,3,4 and 5. Conclusion: Microtensile bond strength was improved significantly after the application of 35% sodium ascorbate when restored with resin composite immediately after bleaching. Grants: This study was funded by NSU, Health Profession Division.
机译:背景:最近已对抗坏血酸钠进行了测试,可以在漂白后立即使用复合材料来扭转复合材料粘结的暂时性减弱。这项研究比较了在有和没有使用35%抗坏血酸钠的情况下,漂白后复合材料的即时粘合和延迟粘合的微拉伸粘合强度。目的:评估35%抗坏血酸钠(SA)(Sigma-Aldrich Co.)对35%过氧化氢(Pola Office / SDI)漂白后立即对牙本质微拉伸粘合强度的影响。方法:收集二十五个健全的人类第三磨牙,以获得一百二十五份标本。牙齿被随机分为五组:Grp1(漂白+立即恢复),Grp2(漂白+延迟恢复),Grp3(漂白+ SA +立即恢复),Grp4(漂白+ SA +延迟恢复),Grp5(无对照治疗) )。漂白之后,但在恢复之前,将Grps 2 2在37°C的去离子水中保存1周。按照制造商的说明,使用Optibond Solo Plus(Kerr)和Filtek Supreme Ultra(3M / ESPE)恢复所有样品。将牙齿切成1x1毫米的条,从每颗牙齿获得大约10条。用万能试验机(Instron,8841型)以0.5mm / min的十字头速度测量微拉伸粘合强度。结果:描述性统计表明,Grp1(阳性对照)显示微张力结合强度显着降低(34.17±10.78)。 Grp5(阴性对照)(45.83±19.32),Grp2(护理标准)(45.36±16.57),Grp3(45.06±20.91)和Grp4(44.73±16.85)显示出统计学上相似的微拉伸粘合强度。单向方差分析用于确定五组之间是否存在明显差异。五组之间的微拉伸粘合强度差异显着(F(4,1073.81)= 3.54,p = .007)Tukey的五组事后比较显示,Grp 1与所有其他组2,3,4之间存在显着差异5.结论:漂白后立即用树脂复合材料恢复35%抗坏血酸钠后,微拉伸粘合强度显着提高。格兰特(Grants):这项研究是由美国国立卫生研究院(NSU)的健康专业部门资助的。

著录项

  • 作者

    Ismail Eman;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号