首页> 美国政府科技报告 >Mine Fire Diagnostics and Implementation of Water Injection with Fume Exhaustion at Renton, PA
【24h】

Mine Fire Diagnostics and Implementation of Water Injection with Fume Exhaustion at Renton, PA

机译:宾夕法尼亚州伦顿矿井火灾诊断及排烟注水实施

获取原文

摘要

U.S. Bureau of Mines research to develop diagnostic methods to locate and evaluate fires in abandoned mines and waste banks and techniques to extinguish such fires was applied to an abandoned 60-acre underground bituminous coal mine (Renton, Allegheny County, PA) to locate and extinguish three separated fire zones. Mine fire diagnostics interpret changes from baseline values in subsurface pressures, temperatures and mine gas composition under imposed pressure gradients induced by a borehole exhaust fan. The effective gas-sampling area surrounding each borehole is greatly enlarged. Sampling iterations, using a 'communicating' boreholes set, provide 'fire signature' information for locating both heated and cold areas. Time-dependent monitoring differentiates heating and cooling periods resulting from combustion front movement and/or fire extinguishment activities. A water injection with fume exhaustion extinguishment effort involved injecting water through boreholes to quench the heated zones while exhaust fans actively removed heated gases from the mine. The technique was ineffective as implemented, primarily because of inadequate spreading of water from the injection points. The Bureau's diagnostic method determined the fire locations and the effectiveness of the water injection with fume exhaustion extinguishment technique.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号