Improvement in the quality of flow visualization in the Langley 0.3-meter transonic cryogenic tunnel

机译:Langley 0.3米跨音速低温隧道的流动可视化质量得到改善

获取原文

摘要

Optical diagnostic techniques have not been as successful in the 0.3-Meter Transonic Cryogenic Tunnel as in conventional wind tunnels. This paper describes a simple shadowgraph experiment which allowed evacuation of the optical paths outside the test section. The results show that refractive index variations induced by temperature gradients outside the test section account for most of the image degradation. Earlier reports had erroneously attributed this degradation to inhomogeneities in the test section. Evacuation of the paths leading to and from the test section significantly improves the quality of flow visualization.