首页> 美国政府科技报告 >Aerodynamic Evaluation of Two Compact Radial-Inflow Turbine Rotors
【24h】

Aerodynamic Evaluation of Two Compact Radial-Inflow Turbine Rotors

机译:两种紧凑型径向流入涡轮转子的气动评估

获取原文

摘要

The aerodynamic evaluation of two highly loaded compact radial turbine rotors wasconducted at the NASA Lewis Research Center Small Engine Component Test Facility (SECTF). The experimental results were used for proof-of-concept, for modeling radial inflow turbine rotors, and for providing data for code verification. Two rotors were designed to have a shorter axial length, up to a 10-percent reduced diameter, a lighter weight, and equal or higher efficiencies with those of conventional radial inflow turbine rotors. Three configurations were tested: rotor 1, having a 40-percent shorter axial length, with the design stator (stator 1); rotor 1 with the design stator vanes closed down (stator 2); and rotor 2, slightly shorter axially and having higher loading, with stator 2. The stator had 36 vanes and the rotors each had 14 solid blades. Although presently uncooled, the rotor blades were designed for thicknesses which would allow cooling passages to be added. The overall stage performance measurements and the rotor and stator exit flow field surveys were obtained. Measurements of steady state temperatures, pressures, mass flow rates, flow angles, and output power were made at various operating conditions. Data were obtained at corrected speeds of 80, 90, 100, 110, and 120 percent of design over a range of equivalent inlet-to-exit pressure ratios of 3.5, 4.0, 4.5, and 5.0, the maximum pressure ratio achieved. The test showed that the configuration of rotor 1 with stator 1 running at the design pressure ratio produced a flow rate which was 5.6 percent higher than expected. This result indicated the need to close down the stator flow area to reduce the flow. The flow area reduction was accomplished by restaggering the vanes. Rotor 1 was retested with the closed-down stator vanes and achieved the correct mass flow. Rotor 2 was tested only with the restaggered vanes. The test results of the three turbine configurations were nearly identical. Although the measured efficiencies of the compact designs fell 2 to 3 points below the predicted efficiency of 91 percent, they did meet and exceed by up to 2.5 percentage points the efficiences of state-of-the-art turbines found in the literature.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号