首页> 美国政府科技报告 >Characterization of an enriched uranyl fluoride deposit in a valve and pipe intersection using time-of-flight transmission measurements with Cf-252
【24h】

Characterization of an enriched uranyl fluoride deposit in a valve and pipe intersection using time-of-flight transmission measurements with Cf-252

机译:使用Cf-252使用飞行时间传输测量表征阀门和管道交叉口中富集的铀酰氟沉积物

获取原文

摘要

A method was developed and successfully applied to characterize large uranyl fluoride (UO2F2) deposits at the former Oak Ridge Gaseous Diffusion Plant. These deposits were formed by a wet air in-leakage into the UF6 process gas lines over a period of years. The resulting UO2F2 is hygroscopic, readily absorbing moisture from the air to form hydrates as UO2F2-nH2O. The ratio of hydrogen to uranium can vary from 0--16, and has significant nuclear criticality safety impacts for large deposits. In order to properly formulate the required course of action, a non-intrusive characterization of the distribution of the fissile material within the pipe, its total mass, and amount of hydration was necessary. The Nuclear Weapons Identification System (NWIS) previously developed at the Oak Ridge Y-12 Plant for identification of uranium weapons components in storage containers was used to successfully characterize these deposits.