首页> 美国政府科技报告 >Measurements of the diffusion of iron and carbon in single crystal NiAl using ion implantation and secondary ion mass spectrometry
【24h】

Measurements of the diffusion of iron and carbon in single crystal NiAl using ion implantation and secondary ion mass spectrometry

机译:用离子注入和二次离子质谱法测量单晶Nial中铁和碳的扩散

获取原文

摘要

Classical diffusion measurements in intermetallic compounds are often complicated by low diffusivities or low solubilities of the elements of interest. Using secondary ion mass spectrometry for measurements over a relatively shallow spatial range may be used to solve the problem of low diffusivity. In order to simultaneously obtain measurements on important impurity elements with low solubilities, the authors have used ion implantation to supersaturate a narrow layer near the surface. Single crystal NiAl was implanted with either (sup 12)C or both (sup 56)Fe and (sup 12)C in order to investigate the measurement of substitutional (Fe) versus interstitial (C) tracer diffusion and the cross effect of both substitutional and interstitial diffusion. When C alone was implanted negligible diffusion was observed over the range of times and temperatures investigated. When both Fe and C were implanted together significantly enhanced diffusion of the C was observed, which is apparently associated with the movement of Fe. This supports one theory of dynamic strain aging in Fe alloys NiAl.