首页> 美国政府科技报告 >Noncontact Surface Thermometry for Microsystems LDRD Final Report
【24h】

Noncontact Surface Thermometry for Microsystems LDRD Final Report

机译:用于微系统的非接触式表面温度计LDRD最终报告

获取原文

摘要

We describe a Laboratory Directed Research and Development (LDRD) effort to develop and apply laser-based thermometry diagnostics for obtaining spatially resolved temperature maps on working microelectromechanical systems (MEMS). The goal of the effort was to cultivate diagnostic approaches that could adequately resolve the extremely fine MEMS device features, required no modifications to MEMS device design, and which did not perturb the delicate operation of these extremely small devices. Two optical diagnostics were used in this study: microscale Raman spectroscopy and microscale thermoreflectance. Both methods use a low-energy, nonperturbing probe laser beam, whose arbitrary wavelength can be selected for a diffraction-limited focus that meets the need for micron-scale spatial resolution. Raman is exploited most frequently, as this technique provides a simple and unambiguous measure of the absolute device temperature for most any MEMS semiconductor or insulator material under steady state operation. Temperatures are obtained from the spectral position and width of readily isolated peaks in the measured Raman spectra with a maximum uncertainty near -10 K and a spatial resolution of about 1 micron. Application of the Raman technique is demonstrated for V-shaped and flexure-style polycrystalline silicon electrothermal actuators, and for a GaN high-electron-mobility transistor. The potential of the Raman technique for simultaneous measurement of temperature and inplane stress in silicon MEMS is also demonstrated and future Raman-variant diagnostics for ultra spatiotemporal resolution probing are discussed. Microscale thermoreflectance has been developed as a complement for the primary Raman diagnostic. Thermoreflectance exploits the small-but-measurable temperature dependence of surface optical reflectivity for diagnostic purposes. The temperaturedependent reflectance behavior of bulk silicon, SUMMiT-V polycrystalline silicon films and metal surfaces is presented. The results for bulk silicon are applied to silicon-on-insulator (SOI) fabricated actuators, where measured temperatures with a maximum uncertainty near -9 K, and 0.75-micron inplane spatial resolution, are achieved for the reflectance-based measurements. Reflectance-based temperatures are found to be in good agreement with Raman-measured temperatures from the same device.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号