Standard B and W Mark-B (15 x 15) pressurized water reactor fuel rods were destructively examined after one cycle of irradiation in the Oconee 1 reactor. Fuel rod average burnup ranged from 10,603 to 11,270 MWd/mtU for the rods examined. Data obtained included fuel rod extraction loads, rod dimensional changes, cladding tensile properties, fuel pellet gap length, fission product distribution, fission gas and crud composition, fuel densification, chemical burnup analysis, and fuel and cladding microstructure. As expected, parametric changes were well within the design envelope. Superficial corrosion and wear were found at spacer grid contact points. However, the 19 rods examined were structurally sound and exhibited no indications of cladding defects associated with pelletcladding interactions. (ERA citation 05:020604)