首页> 美国政府科技报告 >Natural Circulation Steam Generator Model for Optimal Steam Generator Water Level Control
【24h】

Natural Circulation Steam Generator Model for Optimal Steam Generator Water Level Control

机译:最优蒸汽发生器水位控制的自然循环蒸汽发生器模型

获取原文

摘要

Several authors have cited the control of steam generator water level as an important problem in the operation of pressurized water reactor plants. In this paper problems associated with steam generator water level control are identified, and advantages of modern estimation and control theory in dealing with these problems are discussed. A new state variable steam generator model and preliminary verification results using data from the loss of fluid test (LOFT) plant are also presented. (ERA citation 04:054653)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号