首页> 美国政府科技报告 >Local Temperature Rise and Boiling Behavior Behind a Central Blockage in a Wire-Wrapped Pin Bundle
【24h】

Local Temperature Rise and Boiling Behavior Behind a Central Blockage in a Wire-Wrapped Pin Bundle

机译:线包扎针束中心阻塞背后的局部温升和沸腾行为

获取原文

摘要

The succeeding series of central-type blockage experiments were completed by the present one with 61-pin bundle test section. The interpretations of the present test results and those of our previous bundle configurations were summarized in the present paper. Concerning the single-phase flow, an empirical formula was derived to estimate the temperature rises behind various central-type blockages: tauU sub(B)/d sub(h) = 35.3 (D sub(B)/p)sup(0.85), where tauU sub(B)/d sub(h) is the dimensionless residence time and D sub(B)/p is the Ring Parameter newly introduced here. This formula was validated to be effective within the region up to x4 mockup scale (3.0 <= d sub(h) <= 16.1 mm) and was also supported by the data of KfK and ORNL. It was guessed that the apparent peaking factor of temperature rises in the wake region that would be observed in case of bare bundle was about 1.5 and that the effect of three-dimensional distortion due to spacer wires was from 0.9 to 1.2. The estimation of peak temperature rise by the present formula and two kinds of constants led the conclusion that the central-type blockage will not cause local boiling without being detected by an in-core flow-meter. (Atomindex citation 12:629947)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号