Environmental Measurements of Power Plant Cooling Tower and Stack Plumes. Final Report

机译:电厂冷却塔和烟囱羽流的环境测量。总结报告

获取原文

摘要

The focus of this program was to establish the reality and magnitude of any environmental changes caused by the plumes from large evaporative cooling towers through a comprehensive set of measurements taken from a research aircraft. Results are divided into three sections: (1) structure and dynamics of cooling tower plumes; (2) chemical transformation of SO sub 2 to sulfates in coal-fired power plant plumes; and (3) drift deposition studies. (ERA citation 06:023427)