首页> 美国政府科技报告 >Measurement of Magnetically Insulated Line Voltage Using a Thomson Parabola Charged Particle Analyser
【24h】

Measurement of Magnetically Insulated Line Voltage Using a Thomson Parabola Charged Particle Analyser

机译:用Thomson抛物线带电粒子分析仪测量磁绝缘线电压

获取原文

摘要

The absence of direct measurements of magnetically insulated line voltage necessitated reliance on inferred voltages based on theoretical calculation and current measurements. This paper presents some of the first direct measurements of magnetically insulated transmission line peak voltages. These measurements were made on the Sandia National Laboratories HydraMITE facility. The peak voltage is measured by observing the energy of negative ions produced at the line cathode and accelerated through the line voltage. The ion energy and the charge-to-mass ratio are measured using the Thomson Parabola mass spectrometry technique. This technique uses parallel E and B fields to deflect the ions. The deflected ions are detected using a microchannel plate coupled to a phosphor screen and photographic film. The Thomson Parabola results are compared to Faraday Cup measurements and to calculated voltages based on current measurements. In addition, the significance of observed positive ions is discussed. (ERA citation 06:017881)