首页> 美国政府科技报告 >Risk Evaluation of the Containment Overpressure Relief System in a BWR-4, Mark-II Nuclear Power Plant
【24h】

Risk Evaluation of the Containment Overpressure Relief System in a BWR-4, Mark-II Nuclear Power Plant

机译:BWR-4,mark-II核电厂遏制超压减压系统的风险评估

获取原文

摘要

The purpose of this paper is to present a risk evaluation of a Containment Overpressure Relief (COR) system in a BWR-4, Mark-II nuclear power plant. The evaluation is done relative to three risk indices that are related to the frequency of core damage, the early fatalities, and the latent fatalities that might result from an accident in the plant. The evaluation of the COR is based on the Probabilistic Risk Assessment Study of the Limerick Generating Station as it was revised by BNL. Two analyses were performed; one assumes that the design of the plant does not include the COR system and the other assumes that it is included. The risk indices are evaluated in both cases and compared. (ERA citation 08:051244)