首页> 美国政府科技报告 >Humidity in Attics: Sources and Control Methods
【24h】

Humidity in Attics: Sources and Control Methods

机译:attics中的湿度:来源和控制方法

获取原文

摘要

Results are presented which show that the attic is in a constant state of flux, absorbing and releasing moisture. A mathematical model for predicting the moisture content of attic wood members is presented. The model is used to predict hour-by-hour attic air humidity ratio, and seasonal wood moisture content. Results are compared with measured data. The application of the model to the re-calculation of attic ventilation standards is discussed, both with respect to condensation and wood rot. (ERA citation 09:046124)