首页> 美国政府科技报告 >Validity of repeated initial rise thermoluminescence kinetic parameter determinations.
【24h】

Validity of repeated initial rise thermoluminescence kinetic parameter determinations.

机译:重复初始上升热释光动力学参数测定的有效性。

获取原文

摘要

The validity of thermoluminescence (TL) analysis by repeated initial rise measurements has been studied by computer simulation. Thermoluminescence described by 1st Order, 2nd Order, General One Trap and Interactive TL Kinetics was investigated. In the simulation each of the repeated temperature increase and decrease cycles contains a linear temperature increase followed by a decrease appropriate for radiative cooling, i.e. the latter is approximated by a decreasing exponential. The activation energies computed from the simulated emission are readily compared with those used to compute the TL emission. In all cases studied, the repeated initial rise technique provides reliable results only for single peak glow curves or for glow curves containing peaks that do not overlap and, if sufficiently separated, the lowest temperature peak in multipeak curves. Also the temperatures, or temperature cycles corresponding to correct activation energies occur on the low temperature side of the normal glow curve, often well below the peak temperature. A variety of misleading and/or incorrect results an be obtained when the repeated initial rise technique is applied to TL systems that produce overlapping peaks in the usual glow curve. 6 refs., 10 figs.