Bipolar and unipolar tests of 1.5m model SSC collider dipole magnets at Fermilab

机译:费米实验室的1.5米模型ssC对撞偶极磁铁的双极和单极试验

获取原文

摘要

Tests have been performed at Fermilab on 1.5 m magnetic length model SSC collider dipoles using both bipolar and unipolar ramp cycles. Hysteresis energy loss due to superconductor and iron magnetization and eddy currents is measured and compared as a function of various ramp parameters. Additionally, magnetic field measurements have been performed for both unipolar and bipolar ramp cycles. Measurements such as these will be used to estimate the heat load during collider injection for the SSC High Energy Booster dipoles. 9 refs., 4 figs.