Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5-m-long model magnets and eight 15-m-long full-scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500 to 5000 A for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle were digitally integrated to yield the energy loss per cycle. Measurement reproducibility was typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar magnet types agree to within experimental error, while eddy current losses correlate strongly with the observed dependence of quench current on ramp rate.
机译:最近在费米实验室进行了测试,以测量由于涡流,铁和超导体磁化强度造成的能量损失。这些测量是在六个1.5 m长的模型磁体和八个15 m长的全尺寸对撞偶极子磁体上进行的。对于两种类型的磁体,使用从500到5000 A的锯齿斜率,测量交流损耗作为斜率的函数,同时还对一些短磁体进行了双极研究。将完整周期中测得的磁体电压和电流进行数字积分,以产生每个周期的能量损失。测量重现性通常为5%,长磁铁测量与短磁铁测量结果外推法之间具有很好的一致性。相似磁体类型之间的磁化损耗测量结果在实验误差范围内是一致的,而涡流损耗则与观察到的淬火电流对斜坡速率的依赖性密切相关。