首页> 美国政府科技报告 >MATERIAL EVALUATION OF H-ⅡHIGH STRENGTH STEEL FOR F-Ⅲ
【24h】

MATERIAL EVALUATION OF H-ⅡHIGH STRENGTH STEEL FOR F-Ⅲ

机译:F-Ⅲ型H-Ⅱ高强度钢的材料评价

获取原文

摘要

This is indicated by the many different tempering temperatures shown in Tables III and IV. The procedure shown in Table V was used for most of the specimens tested. Although the austenitizing treatments were conducted in a protective endothermic atmosphere, final machining or grinding removed any traces of decarburization. The tensile and shear specimens were tested in a Baldwin Universal Test Machine of 120,OCX) lbs. capacity, equipped with an autographic load-deformation recorder. Fatigue specimens were tested at a stress ratio of R=0.1 in Baldwin SF-10-U and SF-l-U Universal Fatigue Testing Machines equipped with 5:1 load multipliers. The low-cycle fatigue specimens were tested in modified Arcweld Creep Testing Machines of 12,000 lbs. capacity. A stress ratio of B=0 and a frequency of .02 cps. was maintained for all specimens.

著录项

  • 作者

  • 作者单位
  • 年度 1964
  • 页码 1-32
  • 总页数 32
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工业技术;
  • 关键词

相似文献

  • 外文文献
  • 中文文献