首页> 美国政府科技报告 >National Dam Safety Program. Williams Dam (Inventory Number VA 14111). Staunton River Basin. Patrick County, Virginia. Phase I Inspection Report
【24h】

National Dam Safety Program. Williams Dam (Inventory Number VA 14111). Staunton River Basin. Patrick County, Virginia. Phase I Inspection Report

机译:国家大坝安全计划。威廉姆斯大坝(库存号Va 14111)。斯汤顿河流域。弗吉尼亚州帕特里克县第一阶段检查报告

获取原文

摘要

Williams Dam is an earthfill dam about 250 feet long and 28.6 feet high. Based on criteria established by the Department of the Army, Office of the Chief of Engineers (OCE), the Spillway Design Flood (SDF) is the 1/2 PMF. The emergency spillway will pass 11 percent of the PMF or 22 percent of the SDF without overtopping the crest of the dam. The SDF will overtop the dam by a maximum of 2.15 feet, reach an average critical velocity of 5.6 feet per second and flow over the dam for 3.75 hours. Flows overtopping the dam during the SDF are not considered detrimental to the embankment. The spillway is adjudged inadequate but not seriously inadequate. The visual inspection revealed no apparent problems or remedial measures in need of immediate attention. A stability check of the dam is not required. It is recommended that a formal maintenance program and warning system be established.

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号