首页> 外文期刊>PACE: Pacing and clinical electrophysiology >Oxygen uptake to work rate relation throughout peak exercise in normal subjects: relevance for rate adaptive pacemaker programming.
【24h】

Oxygen uptake to work rate relation throughout peak exercise in normal subjects: relevance for rate adaptive pacemaker programming.

机译:正常受试者在整个运动高峰期的摄氧量与工作率之间的关系:与速率自适应起搏器编程的相关性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The oxygen uptake to work rate (VO2/WR) relationship observed throughout peak exercise testing is already being applied for rate adaptive pacemaker programming. However, the detailed curve design of VO2/WR with respect to the anaerobic threshold (AT) has not yet been investigated. It was the purpose of this study to determine the VO2/WR slope below and above the AT in a healthy control group. Seventy-eight healthy control subjects (45.9 +/- 17.4 years; 34 women: 49.9 +/- 18.6 years 44 men: 43.6 +/- 16.6 years) were exercised on a treadmill with "breath-by-breath" gas exchange monitoring using the symptom limited "ramping incremental treadmill exercise" (RITE) protocol. The slope of the VO2/WR relationship from rest to peak exercise (r-p), rest to AT (slope A), and AT to peak exercise (slope B) in mL oxygen uptake per watt of external treadmill work was determined by linear regression analysis. [table: see text] The oxygen uptake to work rate relationship throughout peak exercise in the entire study group generated a significant slope change at the AT (31%, P < 0.0001) with a decreasing slope during higher work load intensities. Female subjects demonstrated a greater percentage of slope change at AT (43%), as compared to men (22%, P < 0.01). When using the oxygen uptake to work rate relationship for the programming of the pacemaker's rate response to exercise, the significant slope change at the AT should be considered to more appropriately pace during higher work intensities supported by anaerobic metabolism. Female pacemaker patients should be programmed to generate a steeper VO2/WR slope below AT with a greater slope change at AT, as compared to men. Abnormally high oxygen uptake to work rate ratios above the AT may be possibly used as an indicator of overpacing.
机译:整个峰值运动测试中观察到的摄氧量与工作速率(VO2 / WR)关系已被用于速率自适应起搏器编程。但是,尚未研究VO2 / WR相对于厌氧阈值(AT)的详细曲线设计。这项研究的目的是确定健康对照组中AT上下的VO2 / WR斜率。在跑步机上锻炼了七十八名健康对照受试者(45.9 +/- 17.4岁; 34名女性:49.9 +/- 18.6岁; 44名男性:43.6 +/- 16.6岁),使用“呼吸-呼吸”气体交换监测仪症状受限的“加速跑步机锻炼”(RITE)协议​​。通过线性回归分析确定从静止到峰值运动(rp),从静止到AT(坡度A),从AT到峰值运动(坡度B)的VO2 / WR关系的斜率,通过线性回归分析确定每瓦外部跑步机工作的氧气吸收量。 [表:参见文本]在整个研究组的整个峰值运动中,摄氧量与工作率的关系在AT处产生了显着的斜率变化(31%,P <0.0001),而在较高的工作负荷强度下斜率减小。与男性(22%,P <0.01)相比,女性受试者在AT处的斜率变化百分比更高(43%)。当使用氧气吸收率与工作率的关系来对起搏器对运动的反应率进行编程时,应考虑AT处的明显斜率变化,以在无氧代谢支持的更高工作强度下更适当地进行步伐。与男性相比,应对女性起搏器患者进行编程,使其在AT以下产生更陡峭的VO2 / WR斜率,在AT处产生更大的斜率变化。高于AT的异常高的摄氧率与工作率之比可能被用作过度搏动的指示。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号