This study investigated the effects of solid retention time (SRT) on sludge characteristics and operational performance in enhanced biological phosphorus removal (EBPR) reactor. The results showed that the reactor operated at SRT of τ = 8.3 d could achieve phosphate removal efficiency η > 90 % and SVI < 100 mL g~(-1). In comparison, increasing SRT to τ = 16.6 d led to a decrease of phosphate removal (η < 85 %) and an increase of SVI value (160 mL g~(-1)), implying a performance degradation and worse settleability of the sludge. In both cases, chemical oxygen demand (COD) removal was observed stable in terms of overall efficiency of η = 90 %. Denaturing gradient gel electrophoresis (DGGE) profiles of sludge revealed a good phylogenetic relationship of sludge with different SRTs. However, the predominant population of community appeared to vary. Especially, the appearance of filamentous microorganisms at longer SRT may be responsible for worse performance and sludge settleability of EBPR system.
机译:这项研究调查了固体保留时间(SRT)对污泥特性和增强型生物除磷(EBPR)反应器运行性能的影响。结果表明,在SRT为τ= 8.3 d下运行的反应器可实现除磷效率η> 90%,SVI <100 mL g〜(-1)。相比之下,将SRT增加到τ= 16.6 d会导致磷酸盐去除量减少(η<85%)和SVI值增加(160 mL g〜(-1)),这意味着污泥的性能下降和沉降性变差。 。在这两种情况下,观察到化学需氧量(COD)去除的总效率η= 90%都是稳定的。污泥的变性梯度凝胶电泳(DGGE)谱表明,不同SRTs的污泥具有良好的系统发育关系。但是,社区的主要人口似乎有所不同。特别是,在较长的SRT时出现丝状微生物可能是EBPR系统的较差性能和污泥沉降能力的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号