首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >Effect of nebulizer/spray chamber interfaces on simultaneous,axial view inductively coupled plasma optical emission spectrometry for the direct determination of As and Se species separated by ion exchange high-performance liquid chromatography
【24h】

Effect of nebulizer/spray chamber interfaces on simultaneous,axial view inductively coupled plasma optical emission spectrometry for the direct determination of As and Se species separated by ion exchange high-performance liquid chromatography

机译:雾化器/喷雾室接口对同时进行的轴向感应耦合等离子体发射光谱的影响,用于直接测定离子交换高效液相色谱法分离的砷和硒

获取原文
获取原文并翻译 | 示例

摘要

Different nebulizer/expansion chamber combinations were evaluated to assess their performance for sample introduction in the direct coupling with an axial view inductively coupled plasma multielement spectrometer for on-line determination of As and Se species previously separated by ion exchange-high performance liquid chromatography.The column effluents were injected into the plasma without prior derivatization.The instrument operation software was adapted for data acquisition and processing to allow multi-wavelength recording of the transient chromatographic peaks.After optimization of the chromatographic operating conditions,separation of mixtures of inorganic As and Se species,and of inorganic and two organic As species (monomethylarsonic and dimethylarsinic acids),was achieved with excellent resolution.Species discrimination from mixtures of As and Se oxyanions was further improved by the simultaneous element detection at specific analytical wavelengths.Three nebulizers and three spray chambers,employed in seven combinations,were tested as interfaces.Concentric nebulizers associated to a glass cyclonic chamber appear most suitable regarding sensitivity and signal to noise ratio.Measured element detection limits (3 sigma) were around 10 ng ml~(-1) for all the species considered,making the method a viable alternative to similar procedures that employ volatile hydride generation previous to sample injection into the plasma.Analytical recoveries both for inorganic and organic species ranged between 92 and 107%.The method was demonstrated to be apt for the analysis of surface waters potentially subjected to natural contamination with arsenic.
机译:评估了不同的雾化器/膨胀室组合,以评估其在直接耦合中的性能,采用轴向观察感应耦合等离子体多元素光谱仪直接测定先前通过离子交换高效液相色谱法分离的砷和硒物种。色谱柱流出物无需事先衍生就被注入血浆中。仪器操作软件适用于数据采集和处理,以允许多波长记录瞬态色谱峰。优化色谱操作条件后,分离无机As和Se的混合物可实现极佳的分离度,同时获得无机和两种有机砷物质(单甲基砷酸和二甲基砷酸)。通过在特定分析波长下同时进行元素检测,进一步改善了砷和硒氧阴离子混合物的物种区分度。三个雾化器和三个测试了以七个组合使用的雾化室作为界面。与玻璃旋风室相关的同心雾化器在灵敏度和信噪比方面似乎最合适。测得的元素检测极限(3σ)约为10 ng ml〜(-1)对于所考虑的所有物种,使该方法成为类似方法的可行替代方法,该方法在将样品注入血浆之前采用挥发性氢化物生成方法。无机和有机物种的分析回收率介于92%至107%之间。该方法被证明是合适的用于分析可能受到砷自然污染的地表水。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号