In the present paper a procedure is proposed for the determination of traces of Cd, Co, Mn and Cr in petroleum industry produced water by inductively coupled plasma optical emission spectrometry. The procedure is based on cloud point extraction of these metals, as their dithizonate complexes, into the surfactant-rich phase of octylphenoxypolyethoxyethanol surfactant (Triton X-114). Extractions were carried out in solutions with salinities between 10%0 and 70%. Since residual salinity in the surfactant-rich phase caused differences in its transport to the plasma, yttrium was used as an internal standard to correct for this effect. The simultaneous metal extraction procedure was optimized by response surface methodology using a Doehlert design and desirability function. Enhancement factors of 21, 21, 9 and 19, along with limits of quantification of 0.093, 0.20, 0.73 and 1.2 mu g L-1, and precision expressed as relative standard deviation (n=8, 20.0 mu g L-1) of 5.8, 1.2, 1.7 and 5.7% were obtained for Cd, Co, Mn and Cr, respectively. The accuracy was evaluated by spike recovery tests on the high salinity water samples with salinity of 40 and 63%. (C) 2007 Elsevier B.V All rights reserved.
机译:本文提出了一种通过电感耦合等离子体发射光谱法测定石油工业采出水中痕量镉,钴,锰和铬的方法。该程序基于将这些金属(作为它们的二硫代膦酸盐络合物)的浊点萃取到辛基苯氧基聚乙氧基乙醇表面活性剂(Triton X-114)的表面活性剂丰富相中。在盐度介于10%0至70%之间的溶液中进行萃取。由于富含表面活性剂的相中的残留盐分会导致其向血浆的传输不同,因此使用钇作为内标来纠正此影响。使用Doehlert设计和期望函数,通过响应面方法优化了同时进行的金属提取程序。增强因子为21、21、9和19,定量极限为0.093、0.20、0.73和1.2μg L-1,精度以相对标准偏差(n = 8,20.0μg L-1)表示Cd,Co,Mn和Cr分别为5.8、1.2、1.7和5.7%。通过加标回收测试对盐度分别为40%和63%的高盐度水样品进行评估。 (C)2007 Elsevier B.V保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号