首页> 外文期刊>Spine >The validity of the SRS-22 instrument in an adult spinal deformity population compared with the Oswestry and SF-12: a study of response distribution, concurrent validity, internal consistency, and reliability.
【24h】

The validity of the SRS-22 instrument in an adult spinal deformity population compared with the Oswestry and SF-12: a study of response distribution, concurrent validity, internal consistency, and reliability.

机译:与Oswestry和SF-12相比,SRS-22仪器在成人脊柱畸形人群中的有效性:研究反应分布,并发有效性,内部一致性和可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: Prospective analysis of a consecutive cohort of adult spinal deformity patients queried over a 12-month period. OBJECTIVES: To assess the SRS-22 instrument compared with the SF-12 and Oswestry. SUMMARY OF BACKGROUND DATA: Very few reports in the literature have applied the SRS-22 to adult spinal deformity patients. METHODS: Consecutive adult spinal deformity patients were applied the SRS-22, SF-12, and Oswestry. Four analyses were done: 1) floor/ceiling effect; 2) Pearson's correlation coefficients between the SRS-22, SF-12, and Oswestry; 3) Cronbach's alpha analysis for internal consistency within the SRS-22; and 4) test/retest. RESULTS: Floor/ceiling range for the SRS-22 compared favorably with the SF-12 and Oswestry. The Pearson's coefficients correlating the two questionnaires relative to the SRS-22 were > 0.7. The Cronbach's alpha within each domain for the SRS-22 were > 0.7, except for pain (0.67). Test/retest correlation coefficients ranged from 0.84 to 0.95 for the subscales. CONCLUSIONS: The SRS-22 is a disease-specific instrument with the capacity to demonstrate change in health status more effectively than the SF-12 and in more domains than the Oswestry. The SRS-22 showed high criterion validity with the SF-12 and Oswestry based on Pearson's coefficients. High Cronbach's alpha scores suggested a high internal consistency within each domain of the SRS-22, except for pain (0.67). Test/retest reliability was excellent.
机译:研究设计:前瞻性分析连续12个月内查询的成人脊柱畸形患者队列。目的:评估SRS-22仪器与SF-12和Oswestry的比较。背景数据概述:文献中很少有报道将SRS-22用于成人脊柱畸形患者。方法:连续性成人脊柱畸形患者应用SRS-22,SF-12和Oswestry。进行了四个分析:1)地板/天花板效果; 2)SRS-22,SF-12和Oswestry之间的Pearson相关系数; 3)Cronbach对SRS-22内部一致性的alpha分析;和4)测试/重新测试。结果:SRS-22的地板/天花板范围比SF-12和Oswestry更好。相对于SRS-22,将两个问卷相关的Pearson系数> 0.7。除了疼痛(0.67)外,SRS-22每个域内的Cronbachα均> 0.7。对于子量表,测试/重新测试的相关系数在0.84至0.95的范围内。结论:SRS-22是一种针对疾病的仪器,具有比SF-12更有效地证明其健康状况变化的能力,并且比Oswestry更能证明其健康状况。根据皮尔逊系数,SRS-22与SF-12和Oswestry相比具有很高的标准有效性。高Cronbach的alpha分数表明,SRS-22的每个域内的内部一致性都很高,除了疼痛(0.67)。测试/重新测试的可靠性非常好。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号