Background: Transcranial Doppler ultrasound detection of weak embolic signals is inhibited by intrinsic limitations within the human auditory system. Psychoacoustics effects are likely to be exacerbated in a clinical environment, where automated embolus detection has potential to surpass manual detection. In this study we quantify the impact of clinical environment on manual detection of Doppler embolic signals following carotid surgery. We also discuss the implications of psychoacoustics considerations for the evaluation of automated detection systems. Method: Concurrent monitoring by vascular technologists and an automated embolus detection system were performed for 50 consecutive patients during postoperative recovery. Both detection methods were evaluated against a majority decision human expert panel analyzing under ideal conditions. Results: Clinical environment reduced the overall sensitivity of manual monitoring by approximately 23%, mainly due to a approximately 2-dB increase in the lower threshold for detection. Clinical environment was also associated with a reduction in positive predictive value for manual detection of approximately 9% compared to ideal conditions. Automated monitoring, which is not affected by environment, was marginally more sensitive for detection of weaker embolic signals. Conclusions: One in 4 weak embolic signals was missed during routine clinical monitoring compared to ideal conditions. Automated detection (in this study) performed slightly better than human observers but did not approach the performance of the majority decision panel. Copyright (c) 2007 S. Karger AG, Basel.
机译:背景:人类听觉系统内在的局限性抑制了经颅多普勒超声检测弱栓塞信号。在临床环境中,自动栓子检测的潜力可能会超过人工检测,因此在临床环境中可能会加剧心理声学的影响。在这项研究中,我们量化了颈动脉手术后临床环境对手动检测多普勒栓塞信号的影响。我们还将讨论心理声学因素对自动检测系统评估的影响。方法:在术后恢复期间,对连续50例患者进行了血管技术人员的并发监测和自动栓塞检测系统。两种检测方法均根据在理想条件下的多数决策人类专家小组进行评估。结果:临床环境将手动监测的总体灵敏度降低了约23%,这主要是由于检测下限的阈值提高了约2dB。与理想情况相比,临床环境还可能导致手动检测的阳性预测值降低约9%。不受环境影响的自动监控对于检测较弱的栓塞信号更为敏感。结论:与理想情况相比,常规临床监测过程中错过了四分之一的弱栓塞信号。自动化检测(在本研究中)的性能略高于人类观察者,但未达到多数决策小组的水平。版权所有(c)2007 S.Karger AG,巴塞尔。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号