This paper describes an active filter topology to improve the performance of hysteresis direct torque control (HDTC) of interior permanent magnet synchronous motor (IPMSM). The filter topology consists of an active filter and two RLC filters, and is connected to the main power circuit through a 1:1 transformer. The active filter is characterized by detecting the harmonics in the motor phase voltages and injecting equivalent harmonic voltages to produce almost sinusoidal voltage waveform to the motor terminals. The active filter uses hysteresis voltage controller while the motor main circuit uses hysteresis direct torque control. The simulation results of this combined control structure show considerable torque ripple reduction in the steady state range and adequate dynamic torque performance as well as considerable harmonic voltage and EMI noise reduction.
机译:本文介绍了一种有源滤波器拓扑,以改善内部永磁同步电动机(IPMSM)的磁滞直接转矩控制(HDTC)的性能。滤波器拓扑由一个有源滤波器和两个RLC滤波器组成,并通过1:1变压器连接到主电源电路。有源滤波器的特征在于检测电动机相电压中的谐波并注入等效谐波电压,以在电动机端子上产生几乎正弦的电压波形。有源滤波器使用磁滞电压控制器,而电机主电路使用磁滞直接转矩控制。这种组合控制结构的仿真结果表明,在稳态范围内转矩脉动减小明显,动态转矩性能适当,谐波电压和EMI噪声均减小。