首页> 外文期刊>Scandinavian journal of rheumatology >Feasibility and reproducibility of the PsAMRIS-H score for psoriatic arthritis in low-field-strength dedicated extremity magnetic resonance imaging
【24h】

Feasibility and reproducibility of the PsAMRIS-H score for psoriatic arthritis in low-field-strength dedicated extremity magnetic resonance imaging

机译:低场强度专用四肢磁共振成像中银屑病关节炎的PsAMRIS-H评分的可行性和可重复性

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objectives: The psoriatic arthritis magnetic resonance imaging scoring system (PsAMRIS-H) for the evaluation of inflammatory and destructive changes in PsA hands was validated on 0.6-T scanners. The applicability of the PsAMRIS-H on a low-field MRI system as a well-accepted, low-cost imaging modality was evaluated. Method: In 65 consecutive patients (31 males, median age 52 years), 73 scans on a 0.2-T dedicated extremity MRI system were obtained for evaluation of PsA. Images were scored for synovitis, tenosynovitis, periarticular enhancement, bone erosion, bone oedema, and proliferation, and the PsAMRIS-H score was calculated. The intraclass correlation coefficient (ICC) was calculated and the paired t-test conducted. Results: Intra-reader reliability for the total PsAMRIS-H score was good, with an ICC of 0.81 and 0.77 for readers 1 and 2, respectively, and inter-reader agreement was moderate (0.57 for each reader). However, the PsAMRIS-H score differed significantly between the two readers (22 vs. 31; p < 0.05). When individual components of the PsAMRIS were evaluated, intra- and inter-reader agreement was poor to moderate, especially for tenosynovitis and periarticular inflammation. Conclusions: Low-field 0.2-T MRI is capable of quantifying the PsAMRIS-H with good intra-reader reproducibility. However, low signal-to-noise ratio (SNR), low spatial resolution, and system artefacts limit the application of the PsAMRIS-H, leading to low inter- and intra-reader agreement for individual features.
机译:目的:在0.6-T扫描仪上验证了用于评估PsA手中炎性和破坏性变化的银屑病关节炎磁共振成像评分系统(PsAMRIS-H)。评估了PsAMRIS-H在低场MRI系统上作为一种公认的低成本成像方式的适用性。方法:连续65例患者(男31例,中位年龄52岁)中,在0.2-T专用肢体MRI系统上进行了73次扫描,以评估PsA。对图像进行滑膜炎,腱鞘炎,关节周围增强,骨侵蚀,骨水肿和增殖评分,并计算PsAMRIS-H评分。计算组内相关系数(ICC)并进行配对t检验。结果:阅读器内部的PsAMRIS-H总评分信度良好,阅读器1和2的ICC分别为0.81和0.77,阅读器间的同意度中等(每个阅读器为0.57)。但是,两个阅读器之间的PsAMRIS-H得分差异显着(22比31; p <0.05)。当评估PsAMRIS的各个组成部分时,阅读器内和阅读器之间的一致性差到中度,尤其是腱鞘炎和关节周围炎。结论:低场0.2-T MRI能够定量PsAMRIS-H,具有良好的阅读器内部再现性。但是,低信噪比(SNR),低空间分辨率和系统伪像限制了PsAMRIS-H的应用,从而导致阅读器之间和内部阅读器对单个功能的一致性较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号