The purpose of this article is to present a method to equalize power imbalances in single-phase loads driven by three-phase voltage source inverters. The objective is to unbalance the line-to-line voltages in order to equalize the individual load power. The method is evaluated under non-linear loads, considering the dispersion of the high-voltage transformer electrical parameters values usually found in ozone generating systems. Two methods are considered for equalizing the load power. In the progressive method, the power equalization is performed by a microcontroller and works setting up the voltage applied over each load in response to power feedback from the other loads. In addition, Fuzzy Logic concepts are also applied, permitting a fast response, in spite of lower precision in the power balancing. Analytical, simulation and experimental results validate both methods.
机译:本文的目的是提出一种均衡由三相电压源逆变器驱动的单相负载中的功率不平衡的方法。目的是使线间电压不平衡,以均衡各个负载功率。考虑到通常在臭氧发生系统中发现的高压变压器电参数值的分散性,在非线性负载下评估该方法。考虑两种方法来均衡负载功率。在渐进式方法中,功率均衡由微控制器执行,并根据来自其他负载的功率反馈来设置施加在每个负载上的电压。此外,尽管功率平衡的精度较低,但也应用了模糊逻辑概念,可实现快速响应。分析,仿真和实验结果验证了这两种方法。