By analyzing the coal mine working face ventilation and cooling cost after mechanical method is adopted for temperature decrease, the relationship between air volume and ventilation cooling cost was established. And through mathematical analysis and specific applications of the model, the reasonable air volume is determined. With respect to the actual conditions of a coal mine, the air volume is figured out. In order to verify the correctness of the air volume by the new method, the Ansys model of ventilation cooling for the working face is established, and the effect of cooling under the air volume is simulated. The simulation results can meet the mine cooling requirement after being applied in coal mine, the cooling effect and the economic benefit are satisfactory.
机译:通过采用机械方法降温后对煤矿工作面通风降温费用进行分析,建立了风量与通风降温费用之间的关系。并通过数学分析和模型的具体应用,确定了合理的风量。根据煤矿的实际情况,计算出风量。为了验证新方法对风量的正确性,建立了工作面通风冷却的Ansys模型,并模拟了风量下的冷却效果。仿真结果可以满足煤矿应用后的冷却要求,冷却效果和经济效益均令人满意。