The objective of this article was to assess the long-term follow-up of the first 26 computer-assisted total knee arthroplasties (TKAs) performed between January, 1997, and December, 1998, using the prototype of the OrthoPilot (B. Braun Aesculap, Tuttlingen, Germany). Three patients died of unrelated causes at 3, 8, and 9 years after surgery and one was lost to follow-up. One prosthesis was partially revised after 5 years of follow up, because of untimely wear of the polyethylene. Another will be revised because of femoral implant loosening. Therefore, results are based on 20 prostheses after a mean follow up of 98.25 +/- 10.28 months (range, 80-119), with a survival rate of 90%. The majority of patients reported being satisfied or very satisfied with their prosthesis (17 patients; 85%), and three (15%) could not benefit fully from the prosthesis because of other issues, including spinal handicap, non operated homolateral coxarthrosis, and Parkinson 's disease.
机译:本文的目的是使用OrthoPilot(B. Braun Aesculap)的原型,评估1997年1月至1998年12月之间进行的前26例计算机辅助全膝关节置换术(TKA)的长期随访情况。 (德国图特林根)。 3例患者在术后3、8和9年死于无关原因,其中1例因随访失败。 5年的随访后,由于聚乙烯的不适当磨损,部分假体得到了部分修复。另一种将因股骨植入物松动而进行修订。因此,结果基于20个假体,平均随访98.25 +/- 10.28个月(范围80-119),存活率为90%。大多数患者报告对假体感到满意或非常满意(17例; 85%),其中三名(15%)由于其他问题而无法从假体中完全受益,这包括脊椎残障,非手术性同侧髋关节病和帕金森症等的疾病。