One hundred forty-two patients who underwent cemented or uncemented hip replacement were studied radiographically to determine acetabular component wear. Mean duration of follow-up was 58 months (range: 35-92 months). Average linear wear was 0.78 mm (range: 0-1.9 mm), and average wear rate was 0.16 mm/year (range: 0-0.45 mm/year). An increased wear rate per year correlated with a discrepancy >18.3 degrees between contralateral acetabular angle and acetabular cup inclination (P<.005). Statistical analysis revealed no significant correlation between cup inclination and polyethylene wear, which was studied without considering the contralateral hip (P>.3). There was no relationship between polyethylene wear and cup design, weight, and initial polyethylene thickness.
机译:对一百四十二名行骨水泥或非骨水泥髋关节置换术的患者进行了影像学检查,以确定髋臼组件的磨损。平均随访时间为58个月(范围:35-92个月)。平均线性磨损为0.78毫米(范围:0-1.9毫米),平均磨损率为0.16毫米/年(范围:0-0.45毫米/年)。每年增加的磨损率与对侧髋臼角和髋臼杯倾角之间的差异> 18.3度有关(P <.005)。统计分析表明,杯倾斜度与聚乙烯磨损之间无显着相关性,在不考虑对侧髋关节的情况下进行了研究(P> .3)。聚乙烯的磨损与杯的设计,重量和初始聚乙烯厚度之间没有关系。