Intraoral storage phosphor radiography for approximal caries detection and effect of image magnification: comparison with conventional radiography.

机译:口腔内存储磷光照相术可用于龋齿的检测和图像放大效果:与传统射线照相术的比较。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVES: The aim of this study was first to test the newly developed storage phosphor (SP) system Digora for diagnostic accuracy of approximal caries detection with special emphasis on image magnification compared with conventional radiography, and second, to test whether the image surroundings could have an influence on observer performance. DESIGN: SP plates and Ektaspeed films were exposed simultaneously to 50 extracted premolars/molars, and the SP image files were transported to a different platform for processing. Ten observers rated 95 approximal surfaces for caries with four imaging modalities: (1) SP images at dental film size viewed with black surroundings, (2) magnified (x4) images viewed in the same manner, (3) magnified (x4) images viewed with text and graphics framing, and (4) films viewed on a light box. The observations were validated with microscopy. Diagnostic accuracy was calculated as the area beneath the receiver operating characteristic curve (AZ). RESULTS: No significant differences were found between SP images and films. Magnified SP images with text and graphics demonstrated significantly higher AZ values than nonmagnified images both for enamel and dentin, and magnified images with black surroundings demonstrated similar results for dentin. CONCLUSIONS: In this in vitro material the observer performance for approximal caries detection with SP images was comparable to that with Ektaspeed films. The magnified SP images generally showed a significantly higher diagnostic accuracy than the nonmagnified SP images.
机译:目的:本研究的目的首先是测试新开发的存储磷(SP)系统Digora,以检测龋齿的诊断准确性,与传统射线照相相比,其重点是图像放大率;其次,测试图像周围环境是否具有对观察者表现的影响。设计:将SP板和Ektaspeed胶片同时暴露于50个提取的前磨牙/磨牙,然后将SP图像文件传输到另一个平台进行处理。十名观察者对龋的95个近似表面进行了评估,并具有四种成像方式:(1)在黑色环境下以牙科胶片大小观看SP图像,(2)以相同方式观看的放大(x4)图像,(3)观看的放大(x4)图像带有文本和图形框架,以及(4)在灯箱上观看的电影。观察结果用显微镜证实。诊断准确性计算为接收器工作特性曲线(AZ)下方的面积。结果:SP图像和胶片之间没有发现显着差异。带有文本和图形的放大SP图像显示的牙釉质和牙本质的AZ值均高于未放大图像,具有黑色环境的放大图像显示的牙本质也具有相似的结果。结论:在这种体外材料中,用SP图像观察龋齿的观察者性能可与Ektaspeed胶片相媲美。放大的SP图像通常显示出比未放大的SP图像明显更高的诊断准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号