OBJECTIVE: To evaluate the accuracy of proximal caries detection comparing enhanced and unenhanced Siemens Sidexis CCD-based digital images with Ektaspeed Plus films utilizing receiver operating characteristic analysis. STUDY DESIGN: Sixty extracted teeth (24 posterior and 36 anterior) were imaged under identical standardized geometric and exposure conditions. Six observers, using a 5-point confidence scale, rated 120 proximal surfaces for the presence or absence of carious lesions by means of three image modalities: (1) observer enhanced and (2) unenhanced Sidexis displays, and (3) Ektaspeed Plus films. The ground truth was determined by microscopic analysis of ground sections. Receiver operating characteristic curves were generated with calculated areas (AZ) analyzed with analysis of variance for effect of reader, reading, and modality. RESULTS: Analysis of variance demonstrated significant differences among readers, readings and modalities (mean square values of 0.012, 0.005, 0.004, F ratios of 13.604, 5.329, 5.100; p = values of 0.001, 0.043, and 0.030, respectively). Post-hoc paired comparisons of modalities using Tukey's statistic demonstrated that only film and enhanced Sidexis images were different from each other (p = 0.024). AZ scores were 0.7650, 0.7499, and 0.8008 respectively, for unenhanced Sidexis, enhanced Sidexis, and Ektaspeed Plus film. CONCLUSION: Unenhanced digital Sidexis images were equivalent to film for the detection of proximal caries in this in vitro study. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the unenhanced digital and film images.
机译:目的:通过使用接收器工作特性分析,比较增强型和未增强型西门子Sidexis CCD数字图像与Ektaspeed Plus胶片,评估近端龋齿的准确性。研究设计:在相同的标准化几何和暴露条件下对60颗拔牙(后24颗和前36颗)成像。六位观察者使用五点置信度标尺,通过三种图像模式对120个近端表面是否存在龋齿病变进行了评级:(1)观察者增强和(2)未增强的Sidexis显示器,以及(3)Ektaspeed Plus胶卷。地面真相是通过对地面部分进行微观分析确定的。接收器的工作特性曲线是通过计算区域(AZ)生成的,并通过方差分析来分析阅读器,阅读和模态的影响。结果:方差分析表明读者,阅读和方式之间存在显着差异(均方根值为0.012、0.005、0.004,F比为13.604、5.329、5.100; p =值分别为0.001、0.043和0.030)。使用Tukey的统计数据对事态进行事后成对比较,结果表明只有胶卷和增强的Sidexis影像彼此不同(p = 0.024)。未增强的Sidexis,增强的Sidexis和Ektaspeed Plus胶片的AZ分数分别为0.7650、0.7499和0.8008。结论:在这项体外研究中,未增强的数字Sidexis图像相当于用于检测近端龋的胶片。与未增强的数字和胶片图像相比,观察者增强的Sidexis图像显示出统计学上显着较低的诊断准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号