Based on the aberration theory of concave grating [1-3], a method to design aberration-corrected flat-field holographic concave gratings by parameter optimization is introduced. And the influence of different parameters such as the incident angle, effective grating grooves and grating radii on the aberrations at diffracted order -1 is discussed. The results indicate that for a concave grating working in a given spectral range, we can correct aberrations by optimizing the incident angle. In addition, flat-field holographic concave gratings with higher resolution and lower aberration can also be designed by choosing the effective grating grooves and larger grating radius properly.
机译:基于凹面光栅[1-3]的像差理论,介绍了一种通过参数优化设计像差校正的平场全息凹面光栅的方法。并讨论了入射角,有效光栅槽和光栅半径等不同参数对衍射级-1像差的影响。结果表明,对于在给定光谱范围内工作的凹面光栅,我们可以通过优化入射角来校正像差。另外,通过适当选择有效的光栅槽和较大的光栅半径,也可以设计出分辨率较高,像差较小的平面场全息凹面光栅。