For measuring the deflections of the microcantilever biosensor, a reflective grating microcantilevers based on SOI were designed and fabricated, a high precision optical readout approach based on diffraction spectrum balancing feedback control was presented. The diffraction spectrum image was collected by a 12-bit digital area array monochrome CCD. According to the sum gray value of the image which subtracted each other at the balancing position and bending position to control a high precision motorized rotation stage revolve make the sum gray value remained in the balancing position always, then the motorized rotation stage revolving angle is just the cantilever bend angle. The resolution of motorized rotation stage is 35 × 10~(?6) deg, the system practical measurement resolution is 1 × 10~(?4) deg, that is to say, for a length of 250 μm microcantilever, the tip measure resolution is up to 0.043 nm. Measurement results clearly demonstrate that this reflective grating microcantilever biosensor and this read out method have a great potential for biological and chemical applications.
机译:为了测量微悬臂梁生物传感器的挠度,设计并制造了基于SOI的反射光栅微悬臂梁,提出了一种基于衍射谱平衡反馈控制的高精度光学读出方法。衍射光谱图像通过12位数字区域阵列单色CCD收集。根据在平衡位置和弯曲位置相互相减以控制高精度电动旋转台旋转的图像总灰度值,使总灰度值始终保持在平衡位置,则电动旋转台旋转角度为悬臂弯曲角度。电动旋转载物台的分辨率为35×10〜(?6)deg,系统实际测量分辨率为1×10〜(?4)deg,也就是说,对于长度为250μm的微悬臂梁,尖端测量分辨率高达0.043 nm测量结果清楚地表明,这种反射光栅微悬臂生物传感器和这种读出方法在生物和化学应用中具有巨大的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号