BACKGROUND: The aim of this study was to evaluate whether measurements obtained with the Ophthonix Z-View aberrometer (Vista, California) and a Humphrey autorefractor (Zeiss Humphrey, Dublin, California) correlate with standard subjective refraction measurements, based on visual acuity results. METHODS: A retrospective data analysis was completed for 97 patients, age range 18 to 66 years, without evidence of systemic or ocular disease. All data were collected without dilation or cycloplegia. Refractive correction measurements (sphere, cylinder, axis) were converted to power vectors for analysis. RESULTS: Differences-versus-means plots show generally excellent agreement between the results of each instrument and subjective refraction, all r~(2) > 0.77, with the Z-View consistently exhibiting less variability than the autorefractor (AR). Nonetheless, the Z-View tends to undercorrect myopia, whereas the AR tends to overcorrect myopia, with statistically significant mean differences (+-SD) in spherical equivalents with respect to subjective refraction of 0.118 (+-0.311) and -0.193 (+-0.474) diopters (D), respectively. Both instruments tend to overcorrect astigmatism of less than -1.25 and -0.75 D, respectively, in some cases by as much as -0.87 D. Both instruments also tend to err in cylinder axis measurement for low astigmatism, often by more than 10 deg. CONCLUSIONS: The Ophthonix Z-View aberrometer is a useful objective clinical instrument that provides better accuracy than an AR, and its results can be used as a good starting point for a subjective refraction for most patients. It also measures higher-order aberrations not identified by other techniques. However, as with AR results, a spectacle prescription based solely on its measurements may not be appropriate for all patients.
机译:背景:本研究的目的是根据视力结果评估使用Ophthonix Z-View像差计(加利福尼亚州维斯塔)和汉弗莱自动折射仪(蔡司汉弗莱,加利福尼亚州都柏林)获得的测量值是否与标准主观屈光率测量结果相关。方法:回顾性分析了97例年龄在18至66岁之间的患者,没有系统性或眼部疾病的证据。收集所有数据,无扩张或睫状肌麻痹。将屈光矫正测量值(球面,圆柱面,轴)转换为屈光度矢量以进行分析。结果:差异-均值图通常显示每种仪器的结果与主观折射之间的极佳一致性,所有r〜(2)> 0.77,并且Z-View始终表现出比自折射器(AR)更少的变异性。尽管如此,Z-View倾向于矫正近视,而AR则倾向于矫正近视,相对于主观屈光度的0.118(+ -0.311)和-0.193(+- 0.474)屈光度(D)。两种仪器都倾向于分别校正小于-1.25 D和-0.75 D的散光,在某些情况下会高达-0.87D。对于低散光,两种仪器也倾向于在圆柱轴测量中产生误差,通常误差大于10度。结论:Ophthonix Z-View像差仪是一种有用的客观临床仪器,比AR的准确性更高,其结果可作为大多数患者进行主观验光的良好起点。它还可以测量其他技术无法识别的高阶像差。但是,与AR结果一样,仅基于其测量结果的眼镜处方可能并不适合所有患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号