...
首页> 外文期刊>Ophthalmology >Vitreoretinal surgery through multifocal intraocular lenses compared with monofocal intraocular lenses in fluid-filled and air-filled rabbit eyes.
【24h】

Vitreoretinal surgery through multifocal intraocular lenses compared with monofocal intraocular lenses in fluid-filled and air-filled rabbit eyes.

机译:在充满液体和充满空气的兔眼中,通过多焦点人工晶状体与单焦点人工晶状体进行玻璃体视网膜手术。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To compare vitrectomy procedures and visualization of posterior segment structures through multifocal silicone intraocular lenses (IOLs) with the same procedures through monofocal silicone IOLs in rabbit eyes. DESIGN: Experimental study. PARTICIPANTS: Twelve eyes of six rabbits. METHODS: Each rabbit eye underwent phacoemulsification of the lens and posterior chamber implantation of a silicone multifocal or silicone monofocal IOL. The type of IOL (monofocal vs. multifocal) implanted in the first eye of each rabbit was randomly decided. The fellow eye then received the other IOL type. Vitrectomy procedures were performed through the IOLs by using a flat contact lens (part 1) or wide-angled contact lens (part 2) for visualization through fluid-filled (parts 1 and 2) and air-filled (part 2) eyes. MAIN OUTCOME MEASURES: Image quality, stereopsis, and contrast were subjectively graded on a scale of 0 (none) to 4 (excellent) for each eye by each surgeon. RESULTS: In part 1, image quality averaged 4 for the monofocal IOL and 3.6 for the multifocal IOL. Stereopsis averaged 4 for the monofocal IOL and 4 for the multifocal IOL. Contrast averaged 4 for the monofocal IOL and 3.9 for the multifocal IOL. Vitrectomy with retinal surface maneuvers was successfully performed in both pigmented and nonpigmented rabbit eyes through both IOL types. In part 2, image quality, stereopsis, and contrast were rated as 4 for both multifocal and monofocal silicone IOLs. Air-fluid exchange was performed without difficulty. Image quality, stereopsis, and contrast were rated as 4 for air-filled eyes. CONCLUSIONS: Visualization of posterior segment structures through multifocal silicone IOLs was sufficient for retinal surface maneuvers during vitrectomy procedures in both fluid-filled and air-filled rabbit eyes.
机译:目的:比较在兔眼中通过多焦点硅胶人工晶状体(IOL)进行玻璃体切除术的程序和后节结构的可视化,以及通过单焦点硅胶人工晶状体(IOL)的相同程序。设计:实验研究。参与者:六只兔子的十二只眼。方法:每只兔眼均接受晶状体超声乳化术,并采用硅酮多焦点或硅酮单焦点人工晶状体后房植入。随机确定植入每只兔子的第一只眼的IOL的类型(单焦点与多焦点)。然后另一只眼睛接受了另一种IOL。使用平角隐形眼镜(第1部分)或广角隐形眼镜(第2部分)通过人工晶状体进行玻璃体切除术,以便通过充液(部分1和2)和充气(部分2)的眼睛进行可视化。主要观察指标:每位外科医生对每只眼睛的主观评分从0(无)到4(优秀),主观评价图像质量,立体视和对比度。结果:在第1部分中,单焦点IOL的图像质量平均为4,多焦点IOL的图像质量平均为3.6。对于单焦点IOL,立体视平均为4,而对于多焦点IOL,立体视平均为4。单焦点IOL的平均对比度为4,多焦点IOL的平均对比度为3.9。通过两种IOL类型,在有色和无色兔眼中均成功进行了视网膜表面玻璃体切除术。在第2部分中,多焦点和单焦点有机硅IOL的图像质量,立体视和对比度均评定为4。进行空气交换没有困难。充气眼睛的图像质量,立体视和对比度为4。结论:通过多焦点硅树脂人工晶状体可视化后段结构足以在充满液体和充满空气的兔眼玻璃体切除术过程中进行视网膜表面操纵。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号