OBJECTIVE: This study aimed to determine the effect of various suturing techniques on the regularity of postkeratoplasty astigmatism. DESIGN: A prospective clinical trial. PARTICIPANTS: Sixty-two consecutive patients undergoing penetrating keratoplasty by the same surgeon (MB) participated. INTERVENTION: Each patient was assigned to one of four groups according to the suturing technique used (a = 16 interrupted 10-0 nylon sutures; b = 2 running 10-0 nylon sutures, each with 8 bites; c = 2 running 10-0 nylon sutures, each with 12 bites; d = 2 running 10-0 nylon sutures, each with 16 bites). This was the only parameter permitted to be changed in the standard keratoplasty procedure used for all cases. Corneal topography was performed 1, 3, and 6 months after surgery. The astigmatic patterns seen on the corneal maps then were classified into regular (symmetric or asymmetric bowtie patterns) or irregular (distorted bowtie, multiaxial, or other patterns). MAIN OUTCOME MEASURES: Regularity of postkeratoplasty corneal astigmatism was measured. RESULTS: At all postoperative examination times, the percentage of irregular astigmatic patterns was highest in group a and lowest in group d (chi-square test: P < 0.005). Groups b and c showed intermediate values. The entity of the astigmatic error as measured by the simulated K-readings of the topographic maps did not differ significantly in the four groups. CONCLUSIONS: A suturing technique using 2 running sutures with 16 bites each can minimize irregular postkeratoplasty astigmatism as long as sutures are in place, when compared with interrupted sutures or double-running sutures of less than 16 bites.
机译:目的:本研究旨在确定各种缝合技术对角膜移植术后散光规则性的影响。设计:一项前瞻性临床试验。参与者:由同一位外科医生(MB)连续进行穿透性角膜移植术的62例患者参加了研究。干预:根据使用的缝合技术,将每位患者分为四组之一(a = 16根中断的10-0尼龙缝合线; b = 2根运行的10-0尼龙缝合线,每口8咬合; c = 2根运行的10-0尼龙缝合线尼龙缝线,每个缝线有12个咬合; d = 2个10-0尼龙缝线,每个缝线有16个咬合。这是在所有情况下使用的标准角膜移植手术中唯一允许更改的参数。术后1、3和6个月进行角膜地形图检查。然后,将在角膜图上看到的散光图案分为规则的(对称或不对称的领结图案)或不规则的(扭曲的领结,多轴或其他图案)。主要观察指标:测定角膜移植术后角膜散光的规律性。结果:在所有术后检查时间,不规则散光模式的百分比在a组中最高,在d组中最低(卡方检验:P <0.005)。 b组和c组显示中间值。通过地形图的模拟K读数测得的散光误差的实体在四组中没有显着差异。结论:与间断缝合线或少于16个咬合的重复缝合线相比,只要使用适当的缝合线,使用2条连续缝线(每条16咬合)的缝合技术可最大程度地减少不规则角膜移植术后散光。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号