Focal photocoagulation was performed on 18 eyes in 18 diabetes patients; a visual acuity test, fluorescein angiography and automated static threshold perimetry by Octopus automated static perimetry (program 31) were conducted before and 1, 3 and 6 months after krypton laser photocoagulation. Central field sensitivity and total loss were measured by automated static threshold perimetry. Group A (13 eyes) had a total loss of less than 150 dB. In these subjects, mild fluorescein leakage was detected within the area of the vascular arcade. In group B (5 eyes) with a total loss of greater than 150 dB, diffuse fluorescein leakage was also detected outside the vascular arcade. The central field sensitivity was reduced in 2 eyes of group B. The total loss worsened in 8 eyes of group A (61.5%) and 5 eyes of group B (100%). Inspection of photographs gave the impression that the degree of fluorescein leakage and the area of the avascular zone on fluorescein angiography accorded with total loss, thus suggesting that total loss reflects visual functions better than visual acuity or central field sensitivity. Therefore, automated static threshold perimetry appears to be a useful method for estimating visual functions after photocoagulation in diabetic maculopathy patients.
机译:18例糖尿病患者的18只眼进行了局部光凝;在k激光光凝术之前,之后,1、3和6个月进行视力测试,荧光素血管造影术和通过章鱼自动静态视野检查(程序31)进行的自动静态阈值视野检查。中心场灵敏度和总损耗通过自动静态阈值视野测量法测量。 A组(13眼)的总损耗小于150 dB。在这些受试者中,在血管拱廊区域内检测到轻度的荧光素渗漏。在总损失大于150 dB的B组(5只眼)中,在血管拱廊外也发现了扩散的荧光素渗漏。 B组的2眼中央视野敏感度降低。A组的8眼(61.5%)和B组的5眼(100%)的总损失加重。检查照片给人的印象是,荧光素血管造影上的荧光素渗漏程度和血管区域的面积与总损耗相符,因此,总损耗比视觉敏锐度或中央视野灵敏度更好地反映了视觉功能。因此,在糖尿病性黄斑病变患者中,自动静态阈值视野检查似乎是评估光凝后视觉功能的有用方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号