...
首页> 外文期刊>Cell transplantation >Improved histological evaluation of vascularity around an immunoisolation device by correlating number of vascular profiles to glucose exchange.
【24h】

Improved histological evaluation of vascularity around an immunoisolation device by correlating number of vascular profiles to glucose exchange.

机译:通过将血管分布图数量与葡萄糖交换相关联,改进了免疫隔离装置周围血管的组织学评估。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The aim of this study was to determine which vessels are important for the exchange of small molecules, such as glucose, from the microcirculation into an immunoisolation device. Reasonably, those vessels should be the ones of interest in histological evaluations. In a previous study, we examined the diffusion of glucose from the microcirculation into immunoisolation devices that had been implanted subcutaneously in rats for various times (i.e., 1, 2, and 4 weeks and 3 months). The glucose kinetic data were then correlated with the number of vascular profiles within 15 and 250 microm from the device. Significant correlations were found only at 250 microm. To examine the relation further between function and vascularization, we used the histological samples from the previous study and counted vascular profiles within various distances between 15 and 400 microm from the device. The number was then correlated with the already available glucose kinetic data. The highest correlations were found at 75 and 100 microm (p < 0.05). We therefore suggest that vascular profiles within 100 microm should be used when evaluating the vascularity of tissue surrounding an immunoisolation device. We also studied neovascularization asymmetries between the side of the membrane facing the skin and that facing the muscle. At 1 and 2 weeks about half of the devices were mainly vascularized on the side facing the skin, whereas the rest were equally vascularized on the two sides. At 3 months, all devices were well vascularized, and no striking vascularization asymmetries were seen.
机译:这项研究的目的是确定哪些血管对于从微循环到免疫隔离装置的小分子(如葡萄糖)交换至关重要。合理地,这些血管应该是组织学评估中感兴趣的血管。在先前的研究中,我们研究了葡萄糖从微循环扩散到已在大鼠皮下植入不同时间(即1、2、4周和3个月)的免疫隔离设备中的扩散情况。然后将葡萄糖动力学数据与距装置15和250微米内的血管分布图数量相关。仅在250微米处发现显着相关。为了进一步检查功能与血管形成之间的关系,我们使用了先前研究的组织学样本,并在距设备15至400微米之间的不同距离内对血管分布进行了计数。然后将该数字与已经可用的葡萄糖动力学数据相关。发现最大的相关性是在75和100微米之间(p <0.05)。因此,我们建议在评估免疫隔离装置周围组织的血管性时,应使用100微米以内的血管轮廓。我们还研究了面对皮肤的膜和面对肌肉的膜之间的新血管形成不对称性。在第1周和第2周,约有一半的器械主要在面向皮肤的一侧血管化,而其余的在两侧均相等。在3个月时,所有装置的血管化良好,并且未发现明显的血管化不对称性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号