首页> 外文期刊>Rheumatology international. >Utility of an open-source DICOM viewer software (OsiriX) to assess pulmonary fibrosis in systemic sclerosis: preliminary results.
【24h】

Utility of an open-source DICOM viewer software (OsiriX) to assess pulmonary fibrosis in systemic sclerosis: preliminary results.

机译:开源DICOM查看器软件(OsiriX)用来评估系统性硬化症中的肺纤维化的实用工具:初步结果。

获取原文
获取原文并翻译 | 示例
           

摘要

To investigate the utility of an open-source Digital Imaging and Communication in Medicine viewer software-OsiriX-to assess pulmonary fibrosis (PF) in patients with systemic sclerosis (SSc). Chest high-resolution computed tomography (HRCT) examinations obtained from 10 patients with diagnosis of SSc were analysed by two radiologists adopting a standard semiquantitative scoring for PF. Pulmonary involvement was evaluated in three sections (superior, middle and inferior). For the assessment of the extension of PF, the adopted semiquantitative HRCT score ranged from 0 to 3 (0 = absence of PF; 1 = 1-20 % of lung section involvement; 2 = 21-40 % of lung section involvement; 3 = 41-100 % of lung section involvement). Further, a quantitative assessment (i.e. parameters of distribution of lung attenuation such as kurtosis and mean lung attenuation) of PF was independently performed on the same sections by a rheumatologist, independently and blinded to radiologists' scoring, using OsiriX. The results obtained were compared with those of HRCT semiquantitative analysis. Intra-reader reliability of HRCT findings and feasibility of OsiriX quantitative segmentation was recorded. A significant association between the median values of kurtosis by both the quantitative OsiriX assessment and the HRCT semiquantitative analysis was found (p < 0.0001). Moreover, kurtosis correlated significantly with the mean lung attenuation (Spearman's rho = 0.885; p = 0.0001). An excellent intra-reader reliability of HRCT findings among both readers was obtained. A significant difference between the mean time spent on the OsiriX quantitative analysis (mean 1.85 ± SD 1.3 min) and the mean time spent by the radiologist for the HRCT semiquantitative assessment (mean 8.5 ± SD 4.5 min, p < 0.00001) was noted. The study provides the new working hypothesis that OsiriX may be a useful and feasible tool to achieve a quantitative evaluation of PF in SSc patients.
机译:调查开放源代码的医学数字影像和通信查看器软件OsiriX的效用,以评估系统性硬化症(SSc)患者的肺纤维化(PF)。由两名放射科医师对10例诊断为SSc的患者进行的胸部高分辨率计算机断层扫描(HRCT)检查,对PF采用标准半定量评分。在三个部分(上,中,下)评估肺部受累情况。为了评估PF的扩展,采用的半定量HRCT评分范围为0到3(0 =不存在PF; 1 =肺部累及的1-20%; 2 = 21-40%肺节的累及; 3 = 41-100%的肺切片受累)。此外,由风湿病医师在相同的切片上独立地对PF进行定量评估(即肺衰减的分布参数,例如峰度和平均肺衰减),并且使用OsiriX独立地对放射医师的评分不知情。将获得的结果与HRCT半定量分析的结果进行比较。记录了HRCT结果在阅读器内的可靠性以及OsiriX定量分割的可行性。通过定量OsiriX评估和HRCT半定量分析发现峰度的中位数值之间存在显着关联(p <0.0001)。此外,峰度与平均肺衰减显着相关(Spearman的rho = 0.885; p = 0.0001)。获得了两个读者之间HRCT发现的出色的读者内部可靠性。注意到在OsiriX定量分析上花费的平均时间(平均1.85±SD 1.3分钟)与放射科医师在HRCT半定量评估上花费的平均时间(平均8.5±SD 4.5分钟,p <0.00001)之间存在显着差异。该研究提供了新的工作假设,即OsiriX可能是实现SSc患者PF定量评估的有用和可行的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号