The removal of the abnormal form of prion protein i.e. PrP(SC) by filtration steps in the plasma fractionation process has been investigated by immuno-Western blotting. Depth filtration has been shown to be capable of removing scrapie by 2-3 log from certain plasma product intermediates. These include cryoprecipitate supernatant, used for the manufacture of immunoglobulin and albumin, and albumin fraction V, by filtration using Pall Seitz or 3m Cuno depth filters respectively. However no significant removal occurred with immunoglobulin Fraction II after Cuno depth filtration. When 0.2 microm PVDF and Nylon membrane filters were tested, the removal of TSEs from 20% albumin was limited i.e. 0.6-1.3 log. However under protein free conditions using phosphate buffered saline, filtration was not effective in the case of a PVDF filter but very effective i.e. >2.9 log in the case of a Nylon filter.
机译:已经通过免疫Western印迹研究了通过血浆分离过程中的过滤步骤去除病毒蛋白的异常形式即PrP(SC)。深度过滤已显示能够从某些血浆产品中间体中去除2-3 log的瘙痒病。这些包括分别通过使用Pall Seitz或3m Cuno深度过滤器进行过滤而用于生产免疫球蛋白和白蛋白的冷沉淀上清液,以及白蛋白级分V。但是,Cuno深层过滤后,免疫球蛋白馏分II并未发生明显的去除。当测试0.2微米的PVDF和尼龙膜过滤器时,从20%白蛋白中除去TSE是有限的,即0.6-1.3log。但是,在使用磷酸盐缓冲盐水的无蛋白质条件下,对于PVDF过滤器,过滤无效,但对于尼龙过滤器,过滤效率非常高,即> 2.9 log。