Uniformity of activation rate distribution through the human body is extremely important for in vivo analysis of the body elements by neutron activation method. Achieving uniformity can be difficult because of the non-homogenous body shape and compositions. Pre-moderator is one of the most essential parts of the irradiation facility to provide uniform distribution over the sample. The aim of the present study was designation of an optimum pre-moderator, in terms of shape and material, which compensates the destructive effects of body shape and allows a satisfactory uniformity of activation rate in the sample. Our final calculations indicated that using two slabs of paraffin with a thickness of 1.8 cm as a pre-moderator in the presence of a reflector/moderator, achieve the most uniform distribution of activation rate in the body.
机译:通过人体的活化速率分布的均匀性对于通过中子活化方法对体内元素进行体内分析极为重要。由于不均匀的体形和成分,很难实现均匀性。预缓和剂是辐照设备中最重要的部分之一,可以使样品均匀分布。本研究的目的是在形状和材料方面指定最佳的预调节剂,以补偿人体形状的破坏作用并允许样品中活化率的均匀性。我们的最终计算结果表明,在存在反射器/减速器的情况下,使用两块厚度为1.8 cm的石蜡作为预减速器,可以实现体内激活率的最均匀分布。