首页> 外文期刊>Radiation Physics and Chemistry >Effective atomic numbers and electron densities of some human tissues and dosimetric materials for mean energies of various radiation sources relevant to radiotherapy and medical applications
【24h】

Effective atomic numbers and electron densities of some human tissues and dosimetric materials for mean energies of various radiation sources relevant to radiotherapy and medical applications

机译:某些人体组织和剂量材料的有效原子序数和电子密度,用于与放射治疗和医学应用相关的各种辐射源的平均能量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Effective atomic numbers, Z_(eff), and electron densities, n_(eff), are convenient parameters used to characterise the radiation response of a multi-element material in many technical and medical applications. Accurate values of these physical parameters provide essential data in medical physics. In the present study, the effective atomic numbers and electron densities have been calculated for some human tissues and dosimetric materials such as Adipose Tissue (ICRU-44), Bone Cortical (ICRU-44), Brain Grey/White Matter (ICRU-44), Breast Tissue (ICRU-44), Lung Tissue (ICRU-44), Soft Tissue (ICRU-44), LiF TLD-100H, TLD-100, Water, Borosilicate Glass, PAG (Gel Dosimeter), Fricke (Gel Dosimeter) and OSL (Aluminium Oxide) using mean photon energies, E_m, of various radiation sources. The used radiation sources are Pd-103, Tc-99, Ra-226,1-131, lr-192, Co-60, 30kVp, 40kVp, 50kVp (Intrabeam, Carl Zeiss Meditec) and 6 MV (Mohan-6 MV) sources. The E_m values were then used to calculate Z_(eff)-and n_(eff) of the tissues and dosimetric materials for various radiation sources. Different calculation methods for Z_(eff) such as the direct method, the interpolation method and AutQ-Z_(eff) computer program were used and agreements and disagreements between the used methods have been presented and discussed. It has been observed that at higher E_m values agreement is quite satisfactory (Dif. < 5%) between the adopted methods.
机译:有效原子序数Z_(eff)和电子密度n_(eff)是在许多技术和医学应用中用于表征多元素材料的辐射响应的便捷参数。这些物理参数的准确值提供了医学物理学中的重要数据。在本研究中,已计算出某些人体组织和剂量材料(例如脂肪组织(ICRU-44),骨皮质(ICRU-44),脑灰/白质(ICRU-44))的有效原子序数和电子密度。 ,乳房组织(ICRU-44),肺组织(ICRU-44),软组织(ICRU-44),LiF TLD-100H,TLD-100,水,硼硅酸盐玻璃,PAG(凝胶剂量计),Fricke(凝胶剂量计)使用各种辐射源的平均光子能量E_m和OSL(氧化铝)。所使用的辐射源是Pd-103,Tc-99,Ra-226、1-131,lr-192,Co-60、30kVp,40kVp,50kVp(Intrabeam,Carl Zeiss Meditec)和6 MV(Mohan-6 MV)资料来源。然后,将E_m值用于计算各种辐射源的组织和剂量材料的Z_(eff)-和n_(eff)。 Z_(eff)的不同计算方法(例如直接方法,插值方法和Aut​​Q-Z_(eff)计算机程序)已被使用,并且已提出和讨论了所用方法之间的协议和分歧。已经观察到,在较高的E_m值之间,采用的方法之间的一致性非常令人满意(Dif。<5%)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号